|description=[[Image:O2k-Fluorometer.JPG|180px|left|link=O2k-Fluorometer]]
|description=[[Image:O2k-Fluorometer.jpg|200px|left|O2k-FluoRespirometer]] '''High-resolution respirometry, HRR''', is the state-of-the-art approach in mitochondria and cell research to measure respiration in various types of [[mitochondrial preparations]] and [[living cells]] combined with MultiSensor modules.  
'''O2k high-resolution respirometry''' ([http://www.oroboros.at/index.php?high-resolution-respirometry HRR]) is based on the [[Oxygraph-2k|OROBOROS O2k]], combining chamber design, application of oxygen-tight materials, electrochemical and optical sensors, Peltier-temperature control and software features ([[DatLab]]) to obtain the unique sensitive and quantitative resolution of oxygen [[concentration]] and [[oxygen flux]], with a closed-chamber or open-chamber mode of operation ([[Titration-Injection microPump|TIP2k]]).  Standardized calibration of the polarographic oxygen sensor ([[MiPNet06.03 POS-calibration-SOP |static sensor calibration]]), calibration of the sensor response time (dynamic sensor calibration), and evaluation of [[instrumental background oxygen flux]] (systemic flux compensation) provide the experimental basis for high accuracy of quantitative results and quality control in HRR. The most important extension to [[O2k-MultiSensor]] systems is the [[O2k-Fluorometer]].
|info=[[Gnaiger 1995 J Bioenerg Biomembr]], [[Gnaiger 2008 POS]], [[Gnaiger 2001 Respir Physiol]]
}}
{{MitoPedia methods
|mitopedia method=Respirometry, Fluorometry, Spectrophotometry
}}
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=DatLab
}}
[[Image:O2.jpg|left|60px|link=Oxygen|Dioxygen]]


Mitochondrial function and dysfunction have gained increasing interest, reflecting growing awareness of the fact that mitochondria play a pivotal role in human health and disease. HRR combines instrumental accuracy and reliability with the versatility of applicable protocols, allowing practically unlimited addition and combination of substrates, inhibitors, and uncouplers using the [[Oroboros O2k-technology]]. Substrate-uncoupler-inhibitor titration (SUIT) protocols allow the interrogation of numerous mitochondrial pathway and coupling states in a single respirometric assay. Mitochondrial respiratory pathways may be analyzed in detail to evaluate even minor alterations in respiratory coupling and pathway control patterns.


== What is an Oxygraph? ==
The O2k-technology provides sole source instruments, with no other available instrument meeting its specifications for high-resolution respirometry. Technologically, HRR is based on the Oroboros O2k-technology, combining optimized chamber design, application of oxygen-tight materials, electrochemical sensors, Peltier-temperature control, and specially developed software features (DatLab) to obtain the unique sensitive and quantitative resolution of oxygen concentration and oxygen flux, with both, a closed-chamber or open-chamber mode of operation ([[TIP2k-Module|TIP2k]]). Standardized calibration of the polarographic oxygen sensor (static sensor calibration), calibration of the sensor response time (dynamic sensor calibration), and evaluation of instrumental background oxygen flux (systemic flux compensation) provide the experimental basis for high accuracy of quantitative results and quality control in HRR. HRR can be extended for MultiSensor analysis by using the [[O2k-Fluo Smart-Module]]. [[Smart Fluo-Sensor]]s are integrated into the O2k to measure simultaneously fluorometric signals using specific fluorophores. Potentiometric modules are available with ion-selective electrodes (pH, TPP<sup>+)</sup>. The [[PB-Module]] extends HRR to PhotoBiology with accurate control of the light intensity and measurement of photosynthesis. The O2k and the NextGen-O2k support all these O2k-Modules. The [[NextGen-O2k]] all-in-one, however, is unique in supporting Q-Redox and NADH-Redox Modules.
|info=[[Oroboros O2k-technology]]
}}
{{Template:Keywords: O2k-technology}}


::::* <big>'''O2'''k:</big> The [[Oxygraph-2k |O2k]] measures oxygen ([[Oxygen |dioxygen, '''O<sub>2</sub>''']]) as a gas dissolved in aqueous solution.
== MitoPedia: O2k and high-resolution respirometry ==
::::* With the O2k, a graph is displayed not only of oxygen concentration over time, but of '''respiration''' (oxygen consumption, oxygen flux) of biological and biochemical samples.
::::» [[MitoPedia: O2k hardware]]
::::* An Oxygraph is not used for measurement of oxygen concentration in a tissue, but for high-resolution analysis of respiratory activity of biological or biochemical samples transferred into the experimental chamber.
::::» [[MitoPedia: DatLab]]
::::» [[MitoPedia: SUIT]]


::::'''»''' [[MitoPedia: Respiratory states]] [[Image:P.jpg|link=OXPHOS capacity|OXPHOS]] [[Image:R.jpg|link=ROUTINE respiration|ROUTINE]] [[Image:E.jpg|link=ET capacity|ET capacity]] [[Image:L.jpg|link=LEAK respiration|LEAK]]  - [[Image:ROX.jpg|link=Residual oxygen consumption|ROX]]
::::» [[Respirometry]]
::::» [[MitoPedia: Respirometry]]
::::» [http://en.wikipedia.org/wiki/Respirometry Wikipedia: Respirometry]
::::» [[O2k Applications]]




[[Image:O2k-Protocols.jpg|right|230px|link=Gnaiger_2014_MitoPathways|MitoPathways]]
[[Image:O2k-Publications.jpg|left|116px|link=O2k-Publications: Topics|O2k-Publications in the MiPMap]]
::: '''O2k-Publications'''
::::* [[O2k-Publications |O2k-Publications: Chronological]]
::::* [[O2k-Publications: Topics]]


[[File:Pesta 2012 Methods Mol Biol Fig7A.jpg|left|250px|link=Pesta_2012_Methods_Mol_Biol|Pesta and Gnaiger 2012]]


:::: Specific [[substrate-uncoupler-inhibitor titration]] (SUIT) protocols are applied in studies of cell respiration or mitochondrial activity. In such experiments, quantitative information is obtained on selected [[Gnaiger 2012 MitoPathways |biochemical pathways]], particularly of the process of '''[[oxidative phosphorylation]] (OXPHOS)''' in mitochondria and bacteria. Comprehensive OXPHOS analysis leads us beyond the highly informative process of oxygen consumption, when high-resolution respirometry is combined with [[O2k-MultiSensor]] Modules to measure simultaneously the production of reactive oxygen species or mitochondrial membrane potential, nitric oxide production, acid-base balance or calcium with O2k-Fluorometry or ion selective electrodes. In the O2k, these bioenergetic parameters are always evaluated in combination with the measurement of oxygen concentration and respiration.
{{Template:Keywords: Oxygen signal}}


::: '''Selected references'''
::::* [[Gnaiger 1995 J Bioenerg Biomembr]]
::::* [[Gnaiger 2001 Respir Physiol]]
::::* [[Gnaiger 2008 POS]]
::::* [[Gnaiger 2020 BEC MitoPathways]]
</div>
</div>
<br />


 
{{MitoPedia methods
[[File:O2k-universe.jpg|right|240px|]]
|mitopedia method=Respirometry, Fluorometry, Spectrophotometry
 
}}
::::* <big>O'''2k''':</big> The O2k is the '''2'''<sup>nd</sup> generation of our high-resolution respirometers. The first model was available since [http://www.oroboros.at/?Oroboros1992 1992]. Development of the new O'''2k''' started in '''2k''' (2000) and the first O'''2'''k was delivered in [http://www.oroboros.at/?Oroboros2002 '''2'''00'''2'''].
{{MitoPedia O2k and high-resolution respirometry
 
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Respirometry, O2k-FluoRespirometry
 
}}
 
::::* <big>O2'''k''':</big> The O2k has two experimental chambers ('''k''': Kammern, German for chambers). [http://www.oroboros.at/?Oxygraph-2k Why 2 ml?]
 
 
 
::::* <big>'''Power-O2k''':</big> Several O2k units are operated simultaneously ('''P'''1, '''P'''2, ..) to combine high-resolution respirometry with [[Power-O2k |high-ouput]].
 
 
 
::::* '''<big>[[Oxygraph-2k |O2k by OROBOROS - tested and trusted]]</big>'''
 
 
== MitoPedia: O2k and high-resolution respirometry ==
::::» [[MitoPedia: O2k hardware]]
::::» [[MitoPedia: DatLab]]
 
 
== Links ==
::::'''»''' [[MitoPedia: Respiratory states]] [[Image:P.jpg|link=OXPHOS capacity|OXPHOS]] [[Image:R.jpg|link=ROUTINE respiration|ROUTINE]] [[Image:E.jpg|link=ETS capacity|ETS]] [[Image:L.jpg|link=LEAK respiration|LEAK]]  - [[Image:ROX.jpg|link=Residual oxygen consumption|ROX]]
::::* [[Respirometry]]
::::* [[MitoPedia: Respirometry]]
::::* [http://en.wikipedia.org/wiki/Respirometry Wikipedia: Respirometry]

Latest revision as of 09:09, 2 April 2024


high-resolution terminology - matching measurements at high-resolution


High-resolution respirometry

Description

O2k-FluoRespirometer

High-resolution respirometry, HRR, is the state-of-the-art approach in mitochondria and cell research to measure respiration in various types of mitochondrial preparations and living cells combined with MultiSensor modules.

Mitochondrial function and dysfunction have gained increasing interest, reflecting growing awareness of the fact that mitochondria play a pivotal role in human health and disease. HRR combines instrumental accuracy and reliability with the versatility of applicable protocols, allowing practically unlimited addition and combination of substrates, inhibitors, and uncouplers using the Oroboros O2k-technology. Substrate-uncoupler-inhibitor titration (SUIT) protocols allow the interrogation of numerous mitochondrial pathway and coupling states in a single respirometric assay. Mitochondrial respiratory pathways may be analyzed in detail to evaluate even minor alterations in respiratory coupling and pathway control patterns.

The O2k-technology provides sole source instruments, with no other available instrument meeting its specifications for high-resolution respirometry. Technologically, HRR is based on the Oroboros O2k-technology, combining optimized chamber design, application of oxygen-tight materials, electrochemical sensors, Peltier-temperature control, and specially developed software features (DatLab) to obtain the unique sensitive and quantitative resolution of oxygen concentration and oxygen flux, with both, a closed-chamber or open-chamber mode of operation (TIP2k). Standardized calibration of the polarographic oxygen sensor (static sensor calibration), calibration of the sensor response time (dynamic sensor calibration), and evaluation of instrumental background oxygen flux (systemic flux compensation) provide the experimental basis for high accuracy of quantitative results and quality control in HRR. HRR can be extended for MultiSensor analysis by using the O2k-Fluo Smart-Module. Smart Fluo-Sensors are integrated into the O2k to measure simultaneously fluorometric signals using specific fluorophores. Potentiometric modules are available with ion-selective electrodes (pH, TPP+). The PB-Module extends HRR to PhotoBiology with accurate control of the light intensity and measurement of photosynthesis. The O2k and the NextGen-O2k support all these O2k-Modules. The NextGen-O2k all-in-one, however, is unique in supporting Q-Redox and NADH-Redox Modules.

Abbreviation: HRR

Reference: Oroboros O2k-technology


Questions.jpg


Click to expand or collaps


MitoPedia: O2k and high-resolution respirometry

» MitoPedia: O2k hardware
» MitoPedia: DatLab
» MitoPedia: SUIT
» MitoPedia: Respiratory states OXPHOS ROUTINE ET capacity LEAK - ROX
» Respirometry
» MitoPedia: Respirometry
» Wikipedia: Respirometry
» O2k Applications


O2k-Publications in the MiPMap
O2k-Publications



Questions.jpg


Click to expand or collaps


Selected references



MitoPedia methods: Respirometry, Fluorometry, Spectrophotometry 


MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Respirometry, O2k-FluoRespirometry