Difference between revisions of "Cover-Slip\black"
From Bioblast
Line 7: | Line 7: | ||
|product image=[[Image:Cover-Slip_black.JPG|180px|right]] | |product image=[[Image:Cover-Slip_black.JPG|180px|right]] | ||
}} | }} | ||
* Cover-Slips cannot be placed on top of the stoppers in O2k-MultiSensor applications with additional sensors inserted through the stopper, or while [[TIP2k]] needles are inserted into the O2k-chamber. | ::::* Cover-Slips cannot be placed on top of the stoppers in O2k-MultiSensor applications with additional sensors inserted through the stopper, or while [[TIP2k]] needles are inserted into the O2k-chamber. | ||
* The black cover-slips replaced the previous perspex [[Cover-Slip]]s (Product ID 24410-01). They are functionally identical, but the black cover slips take into account the optical properties of the [[O2k-Fluorometer]] and prevent light from penetrating through the capillaries of the stoppers when using optical sensors. | ::::* The black cover-slips replaced the previous perspex [[Cover-Slip]]s (Product ID 24410-01). They are functionally identical, but the black cover slips take into account the optical properties of the [[O2k-Fluorometer]] and prevent light from penetrating through the capillaries of the stoppers when using optical sensors. | ||
== Keywords == | |||
{{Template:Keywords: Chamber volume}} |
Revision as of 18:21, 18 October 2020
Cover-Slip\black
Description | A Cover-Slip should be placed on top of the O2k-Stopper to minimize contamination and evaporation of liquid extruding from the capillary of the stopper. The Cover-Slips do not exert any direct effect on oxygen backdiffusion into the O2k-chamber. Use the the Cover-Slip\black to avoid light penetration and disturbance of fluorescence signals and generally for optical measurements in the O2k.
Two units of this item are standard components of the O2k-Assembly Kit. |
---|---|
Product ID | 24411-01 |
Type | O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper |
Link | |
Image |
- Cover-Slips cannot be placed on top of the stoppers in O2k-MultiSensor applications with additional sensors inserted through the stopper, or while TIP2k needles are inserted into the O2k-chamber.
- The black cover-slips replaced the previous perspex Cover-Slips (Product ID 24410-01). They are functionally identical, but the black cover slips take into account the optical properties of the O2k-Fluorometer and prevent light from penetrating through the capillaries of the stoppers when using optical sensors.
Keywords
- »Bioblast links: Chamber volume - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>>
- » Volume
- Units: Liter [L]; 1 L = 1 dm3 = 10-3 m3; 1 mL = 1 cm3; 1 µL = 1 mm3
- » Volume
- On chamber volume
- Components of the experimental O2k-chambers
- » Stirrer-Bar\white PVDF\15x6 mm
- » Stirrer-Bar sV\white PVDF\11.5x6.2 mm
- » Stopper\black PEEK\conical Shaft\central Port
- » Stopper sV\black PEEK\conical Shaft\central Port
- » O-ring\Viton\12.5x1 mm
- » O-ring sV\Viton\9.5x1 mm
- » Volume-Calibration Ring
- » Volume-Calibration Ring sV
- » Stopper-Spacer
- » Cover-Slip\black
- » O2k-Chamber Holder
- » O2k-Chamber Holder sV
- » OroboPOS-Holder
- » OroboPOS-Holder sV
- Maintencance