Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Search results

From Bioblast
Results 1 – 22 of 22
Advanced search

Search in namespaces:

  
  
  
  
  
  
  
  
  
  
  
  
  

Page title matches

Page text matches

  • #REDIRECT [[OroboPOS-Holder]]
    29 bytes (2 words) - 20:10, 15 January 2012
  • #REDIRECT [[OroboPOS-Holder]]
    29 bytes (2 words) - 18:05, 10 November 2020
  • ...sealing the O2k-Chamber sV with the [[POS-Seal Tip]]. In addition, the POS-Holder sV fixes the O2k-Chamber sV in an accurate rotational position by pressing |info=[https://www.oroboros.at/index.php/product/orobopos-holder-sv/'''Product details and purchase information''']
    865 bytes (123 words) - 11:09, 27 July 2023
  • ...or sealing the O2k-chamber with the [[POS-Seal Tip]]. In addition, the POS-Holder fixes the O2k-Chamber in an accurate rotational position by pressing agains |info=[https://www.oroboros.at/index.php/product/orobopos-holder/ '''Product details and purchase information''']
    2 KB (351 words) - 11:13, 27 July 2023
  • ...g]] during membrane application. Since the O2k-Series G-0075 membrane ring holder have a 2 mm extended ridge for a better grip. |info=[https://www.oroboros.at/index.php/product/orobopos-mounting-tool/ '''Product details and purchase information''']
    874 bytes (115 words) - 11:36, 25 July 2023
  • ...roboPOS]]. Two [[O2k-Chamber Holder]]s, two [[OroboPOS-Holder]]s and two [[OroboPOS-Connector]]s are attached to the O2k-Main Unit for transport. ...PNet22.11_O2k-FluoRespirometer_manual]]) and store the O2k-Chambers in the OroboPOS-Service Kit box.
    7 KB (1,045 words) - 13:07, 9 November 2023
  • ...Gzb0KfYwTQ&list=PLT4umseflf-m6O1sApyn9doi8vHNAKaIs&index=4 '''A3''' Insert OroboPOS] .../watch?v=cjsdZbvT8qc]] [https://www.youtube.com/watch?v=cjsdZbvT8qc Insert OroboPOS]
    9 KB (1,435 words) - 12:42, 14 November 2023
  • ...k]] is transmitted from the electrochemical polarographic oxygen sensor ([[OroboPOS]]) for each of the two O2k-chambers to [[DatLab]]. The primary signal is a ...chamber the chamber may have been improperly positioned, with the blue POS holder (on the left or right side of the copper block) screwed too far into the ch
    9 KB (1,446 words) - 11:18, 9 April 2024
  • ...omponent of [[MitoPedia: Oroboros QM |Oroboros Quality Management]]. The [[OroboPOS]] test is described in detail in [[MiPNet06.03 POS-calibration-SOP]], is pe ::::The O2 sensor test does not only serve to evaluate the function of the OroboPOS, but many other components of the O2k have to function according to specifi
    10 KB (1,476 words) - 09:52, 5 April 2024
  • ...[File:32100-01.jpg|right|180px]] || [[O2k-Chamber Holder]] [[Image:Chamber holder PVDF Stopper.jpg|right|180px]] ...|| [[OroboPOS-Holder sV]] [[File:32300-01.jpg|right|180px]] || [[OroboPOS-Holder]] [[Image:Pos_holder.JPG|right|180px]]
    12 KB (1,709 words) - 13:03, 5 February 2024
  • ::::* Type of [[Catalogue O2k-Stoppers|stoppers]] and [[O2k-Chamber Holder|chamber holders]] used ::::* Type of [[OroboPOS-Connector]]
    2 KB (373 words) - 08:50, 11 November 2019
  • :::: 15:30 - 16:00 Sample Holder – hands on :::: 16:00 - 17:00 General questions (OroboPOS-Connector, quality control…)
    3 KB (374 words) - 06:27, 13 May 2023
  • ...to a technical issue with the O2k-Main Unit, the OroboPOS-Connector, the OroboPOS or a bad electrical connection between these components. The high zero curr Get immediate information on how satisfactory your OroboPOS response time is by performing a [[Stirrer_test|stirrer test]] during [[Air
    27 KB (4,026 words) - 11:53, 29 March 2021
  • ...mpleted in 2004, to improve the design of the polarographic oxygen sensor (OROBoPOS), which is available since November 2004. ...xia], [https://www.oroboros.at/index.php/product/sample-holder-set/ Sample Holder]
    8 KB (1,102 words) - 16:18, 22 February 2024
  • ::::## [[OroboPOS-Holder]] not properly positioned. ::::## [[O2k-Chamber Holder]] not properly positioned; V- and O-rings not properly mounted ([[V-ring\30
    19 KB (2,868 words) - 10:11, 22 April 2022
  • Switching off the O2k after use increases the lifespan of the OroboPOS and saves energy <br> | '''A damaged OroboPOS-Holder may cause medium to leak from the O2k-Chamber.'''<br>
    85 KB (11,819 words) - 14:18, 10 January 2022
  • ...to a technical issue with the O2k-Main Unit, the OroboPOS-Connector, the OroboPOS or a bad electrical connection between these components. The high zero curr |'''Noisy oxygen signal? Check the OroboPOS and OroboPOS-Connector to clean the electrical connections.'''<br>
    126 KB (17,785 words) - 08:55, 13 August 2021
  • : '''Oroboros innovation: the Sample Holder''' protecting susceptible samples from damage by stirring in the O2k-chambe : -»[https://www.oroboros.at/index.php/product/sample-holder-set/ Sample Holder Set]«
    87 KB (11,941 words) - 15:14, 16 November 2023

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)