Difference between revisions of "MiPNet18.05 Amplex-Mouse-heart"
Line 1: | Line 1: | ||
{{Publication | {{Publication | ||
|title=[[Image:O2k-Protocols.jpg|right|80px|link=O2k-Protocols|O2k-Protocols]] O2k-Fluorometry: HRR and H<sub>2</sub>O<sub>2</Sub> production in mouse cardiac tissue homogenate. [[ | |title=[[Image:O2k-Protocols.jpg|right|80px|link=O2k-Protocols|O2k-Protocols]] O2k-Fluorometry: HRR and H<sub>2</sub>O<sub>2</Sub> production in mouse cardiac tissue homogenate. | ||
|info=[[File:PDF.jpg|50px|link=http://wiki.oroboros.at/images/2/2a/MiPNet18.05_Amplex-Mouse-heart.pdf |Bioblast pdf]] »[http://www.bioblast.at/index.php/File:MiPNet18.05_Amplex-Mouse-heart.pdf Versions] | |||
|authors=OROBOROS | |authors=OROBOROS | ||
|year=2015-06-16 | |year=2015-06-16 |
Revision as of 12:56, 16 February 2016
O2k-Fluorometry: HRR and H2O2 production in mouse cardiac tissue homogenate. |
» »Versions
OROBOROS (2015-06-16) Mitochondr Physiol Network
Abstract: Eigentler A, Fontana-Ayoub M, Gnaiger E (2015) O2k-Fluorometry: HRR and H2O2 production in mouse cardiac tissue homogenate. Mitochondr Physiol Network 18.05(02):1-6.
The O2k-Fluorescence LED2-Module is an extension of the OROBOROS O2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H2O2 production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H2O2 production.
- >> Product: OROBOROS O2k, O2k-Catalogue
- >> Permeabilized muscle fibres
• O2k-Network Lab: AT Innsbruck OROBOROS, AT Innsbruck MitoCom
Labels: MiParea: Respiration
Organism: Mouse
Tissue;cell: Heart
Preparation: Homogenate
Regulation: Cyt c Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property.
HRR: Oxygraph-2k, O2k-Fluorometer, O2k-Protocol
O2k-Demo, O2k-MultiSensor, Mt-Preparation, PBI-Shredder