Antunes Diana (talk) 08:58, 5 May 2020 (CEST) Format for new Agenda/Alerts entries:
 {|
 | logos
 | title in bold <br>
 - link
 |}
 

e.g.,

O2k-Open SupportWarning: loss of data Did you know that the proper use of TIP2k-Filter Papers may avoid an unstable O2 slope neg. signal during Instrumental background correction?

- »Instrumental background« and »TIP2k Filter Papers«

See the scheme:


Agenda/Alerts body text format


Bioblast alert 2020

Prep for circular done here: Talk:Bioblast alert 2020

MitoPedia alert

Next

O2k-Brief alert

Next

  • May-26 Tu
O2k-brief repository Remodeling of OXPHOS in prostate cancer to potentially damaging mtDNA mutations and differential expression of mt-genes
from the O2k-Network » AT Innsbruck Gnaiger E « and » AT Innsbruck Oroboros « 
  • Schöpf Bernd, Weissensteiner Hansi, Schäfer Georg, Fazzini Federica, Charoentong Pornpimol, Naschberger Andreas, Rupp Bernhard, Fendt Liane, Bukur Valesca, Giese Irina, Sorn Patrick, Sant’Anna-Silva Ana Carolina, Iglesias-Gonzalez Javier, Sahin Ugur, Kronenberg Florian, Gnaiger Erich, Klocker Helmut (2020) OXPHOS remodeling in high-grade prostate cancer involves mtDNA mutations and increased succinate oxidation. Nat Commun 11:1487. - »Bioblast link«

O2k-Publications alert

Next

O2k-Open Support alert

Next

  • While in Home Office: Gnaigere (talk) 14:03, 19 March 2020 (CET) https://wiki.oroboros.at/index.php/Talk:O2k-Open_Support_alert - Many labs will move to home office mode. In line with our special DL7.4 home office offer (see Agenda today), therefore, I suggest to post in our Agenda analysis-linked O2k-Open Support cases during this time, and collect real-time operation cases for future releases.


  • Jun-22 Mo
O2k-Open SupportTake care Did you know how a stirrer test can save your experiments?

Get immediate information on how satisfactory your OroboPOS response time is by performing a stirrer test during air calibration.
For more information, see:
- »MitoPedia« and »Oxygen calibration - DatLab«

  • Jun-29 Mo
O2k-Open SupportWarning: loss of data Find out how to evaluate the effect of the obtained ‘O2 slope neg’ noise on experimental results

- » QC1: Oxygen sensor test«

Removed for correction

O2k-Open SupportWarning: loss of data Do you perform the leaky chamber test after chamber assembly?

An unnoticed leak from the chamber may affect your data, therefore we recommend performing the Leaky chamber test - especially after chamber reassembly.
- »Leaky chamber test« and » https://intern.oroboros.at/index.php/Overnight_test_after_O2k-chamber_assembly«

O2k-Open Support alert circulars

O2k-Open Support alert circular 2020(01): in prep

New O2k-Open SupportWarning: loss of data A damaged OroboPOS-Holder may cause medium to leak from the O2k-Chamber.

See how you can check that the two blue OroboPOS-Holders are intact.
- »O2k-OroboPOS-Holder«

New O2k-Open SupportTake care Calibration parameters are transferred to experimental DatLab files

Save calibration information from selected Marks while DatLab is connected to the O2k during an instrumental calibration run. Air calibration and zero oxygen calibration can be performed and saved in a single DatLab file or in separate DatLab files.
- » Oxygen calibration - DatLab«

O2k-Open SupportWarning: loss of data Do you perform O2k-Chamber volume calibration?

The volume calibration is essential to ensure that the chamber volume is correctly calibrated to its standard volume of 2 mL (or 0.5 mL for the O2k-sV-Module).
- »O2k-Chamber MitoPedia«

O2k-Open SupportTake care Do you use the correct O2 solubility factor (FM) in the ‘O2 calibration’ window in DatLab?

The O2 solubility factor varies according to the medium used and influences the air calibration.
- »Oxygen solubility factor«

In preparation

For discussion

Here we discuss suggestions for the Oroboros Ecosystem Agenda 2020 (if the specific alert section is yet to be attributed)
MitoPedia: SUIT Controlled stability of the MitoKit-CII based on HPLC and LCMS analysis: No degradation of MitoKit-CII compounds MitoKit-CII/Succinate-nv (NV118) and MitoKit-CII/Malonate-nv (NV161) for following storage conditions:
  • Proven -80 °C solid stability for more than 3 years (3 years 7 months)
  • Proven -20 °C solid stability for 1 year
  • Proven DMSO stability at room temperature for 1 week
  • Proven DMSO stability at -20 °C for 6 months (ongoing)