| [[Amplex UltraRed|Amplex<sup>TM</sup> UltraRed]]||[[Fluorescence-Sensor Green]] [[Smart Fluo-Sensor Green]] || [[ Filter Set AmR| AmR]] || [[O2k_signal_and_output|Type II]] || 100 - 500 || 1000 || at c(AmR) = 10 µM
| [[Amplex UltraRed|Amplex<sup>TM</sup> UltraRed]]||[[Fluorescence-Sensor Green]] or [[Smart Fluo-Sensor Green]] || [[ Filter Set AmR| AmR]] || [[O2k_signal_and_output|Type II]] || 100 - 500 || 1000 || at c(AmR) = 10 µM
|-  
|-  
| [[TMRM]]||[[Fluorescence-Sensor Green]] || [[ Filter Set AmR| AmR]] || [[O2k_signal_and_output|Type III]] || 100 - 500|| 1000 || at c(TMRM) = 2 µM
| [[TMRM]]||[[Fluorescence-Sensor Green]]or [[Smart Fluo-Sensor Green]] || [[ Filter Set AmR| AmR]] || [[O2k_signal_and_output|Type III]] || 100 - 500|| 1000 || at c(TMRM) = 2 µM
|-
|-
| [[Safranin]] ||[[Fluorescence-Sensor Blue]]|| [[Filter Set Saf|Saf]] || [[O2k_signal_and_output| Type III]] || 100 - 250  || 1000 || at c(safranin) = 2 µM  
| [[Safranin]] ||[[Fluorescence-Sensor Blue]] or [[Smart Fluo-Sensor Blue]]|| [[Filter Set Saf|Saf]] || [[O2k_signal_and_output| Type III]] || 100 - 250  || 1000 || at c(safranin) = 2 µM  
|-
|-
| [[Rhodamine 123]] ||[[Fluorescence-Sensor Blue]]|| [[Filter Set Saf|Saf]] || [[O2k_signal_and_output| Type III]] || 100 - 250  || 1000 || at c(Rh123) = 1 µM  
| [[Rhodamine 123]] ||[[Fluorescence-Sensor Blue]] or [[Smart Fluo-Sensor Blue]]|| [[Filter Set Saf|Saf]] || [[O2k_signal_and_output| Type III]] || 100 - 250  || 1000 || at c(Rh123) = 1 µM  
|-
|-
| [[Magnesium green|Magnesium Green™]]||[[Fluorescence-Sensor Blue]]|| [[Filter Set MgG / CaG| MgG / CaG]] || [[O2k_signal_and_output| Type I and II]] || 100 - 500|| 1000 || at c(Mg Green) = 2 µM
| [[Magnesium green|Magnesium Green™]]||[[Fluorescence-Sensor Blue]] or [[Smart Fluo-Sensor Blue]]|| [[Filter Set MgG / CaG| MgG / CaG]] || [[O2k_signal_and_output| Type I and II]] || 100 - 500|| 1000 || at c(Mg Green) = 2 µM
|-
|-
| [[Calcium green|Calcium Green™]]||[[Fluorescence-Sensor Blue]]|| [[Filter Set MgG / CaG| MgG / CaG]] || [[O2k_signal_and_output|Type I]] ||300 - 500||  1000 ||at c(Ca Green) = 2 µM
| [[Calcium green|Calcium Green™]]||[[Fluorescence-Sensor Blue]] or [[Smart Fluo-Sensor Blue]]|| [[Filter Set MgG / CaG| MgG / CaG]] || [[O2k_signal_and_output|Type I]] ||300 - 500||  1000 ||at c(Ca Green) = 2 µM
|}
|}
In the O2k-LED2-Module (Series D-G) polarization voltage is used, while in the O2k-Fluo Smart Module (Series H-I) fluorescence intensity. To use the same setting in the O2k-Fluo LED2-Module as in the O2k-Fluo Smart-Module use the following Excel sheet:  
In the O2k-LED2-Module (Series D-G) polarization voltage is used, while in the O2k-Fluo Smart Module (Series H-I) fluorescence intensity. To use the same setting in the O2k-Fluo LED2-Module as in the O2k-Fluo Smart-Module use the following Excel sheet:  

Revision as of 10:23, 19 November 2021

Application Sensor Filter set O2k output Light intensity (Amp polarization voltage) Gain Comment
AmplexTM UltraRed Fluorescence-Sensor Green or Smart Fluo-Sensor Green AmR Type II 100 - 500 1000 at c(AmR) = 10 µM
TMRM Fluorescence-Sensor Greenor Smart Fluo-Sensor Green AmR Type III 100 - 500 1000 at c(TMRM) = 2 µM
Safranin Fluorescence-Sensor Blue or Smart Fluo-Sensor Blue Saf Type III 100 - 250 1000 at c(safranin) = 2 µM
Rhodamine 123 Fluorescence-Sensor Blue or Smart Fluo-Sensor Blue Saf Type III 100 - 250 1000 at c(Rh123) = 1 µM
Magnesium Green™ Fluorescence-Sensor Blue or Smart Fluo-Sensor Blue MgG / CaG Type I and II 100 - 500 1000 at c(Mg Green) = 2 µM
Calcium Green™ Fluorescence-Sensor Blue or Smart Fluo-Sensor Blue MgG / CaG Type I 300 - 500 1000 at c(Ca Green) = 2 µM

In the O2k-LED2-Module (Series D-G) polarization voltage is used, while in the O2k-Fluo Smart Module (Series H-I) fluorescence intensity. To use the same setting in the O2k-Fluo LED2-Module as in the O2k-Fluo Smart-Module use the following Excel sheet:

Download2.png Download the EXCEL calculation-sheet to adjust fluorescence intensity
Download2.png