- P-L control efficiency + ([[File:J(P-L).jpg|50 px|P-L control effici โฆ [[File:J(P-L).jpg|50 px|P-L control efficiency]] The '''''P-L'' control efficiency''' (''P-L'' flux control efficiency) is defined as ''j<sub>P-L</sub>'' = (''P-L'')/''P'' = 1-''L/P''. [[OXPHOS capacity]] corrected for [[LEAK respiration]] is the [[P-L net OXPHOS capacity]], ''P-L''. The ''P-L'' control efficiency is the ratio of net to total OXPHOS capacity, which is equal to the biochemical ''E-L'' coupling efficiency, if ''P''=''E''. ''j<sub>P-L</sub>'' = 1.0 for a fully coupled system (when RCR approaches infinity); ''j<sub>P-L</sub>'' = 0.0 (RCR=1) for a system with zero respiratory phosphorylation capacity (''P-L''=0) or zero [[E-L coupling efficiency |''E-L'' coupling efficiency]] (''E-L''=0 when ''L''=''P''=''E''). If [[State 3]] is measured at saturating concentrations of ADP and P<sub>i</sub> (State 3 = ''P''), then the [[respiratory acceptor control ratio]] RCR equals ''P/L''. Under these conditions, the respiratory control ratio and ''P-L'' control efficiency are related by a hyperbolic function, ''j<sub>P-L</sub>'' = 1-RCR<sup>-1</sup>.</br>ยป [[#Cell ergometry: OXPHOS-control and ET-coupling efficiency |'''MiPNet article''']][#Cell ergometry: OXPHOS-control and ET-coupling efficiency |'''MiPNet article''']])