Search by property

From Bioblast

This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.

Search by property

A list of all pages that have property "Description" with value "'''O2 calibration''' is the calibration in DatLab of the oxygen sensor. It is a prerequisite for obtaining accurate measurements of respiration. Accurate calibration of the oxygen sensor depends on (''1'') equilibration of the incubation medium with air oxygen partial pressure at the temperature defined by the experimenter; (''2'') zero oxygen calibration; (''3'') high stability of the POS signal tested for sufficiently long periods of time; (''4'') linearity of signal output with oxygen pressure in the range between oxygen saturation and zero oxygen pressure; and (''5'') accurate oxygen solubility for aqueous solutions for the conversion of partial oxygen pressure into oxygen concentration. The standard oxygen calibration procedure is described below for high-resolution respirometry with the calibration routine using instrumental calibration DL-Protocols in [[DatLab]].". Since there have been only a few results, also nearby values are displayed.

Showing below up to 2 results starting with #1.

View (previous 50 | next 50) (20 | 50 | 100 | 250 | 500)


    

List of results

    • Oxygen calibration - DatLab  + ('''O2 calibration''' is the calibration in'''O2 calibration''' is the calibration in DatLab of the oxygen sensor. It is a prerequisite for obtaining accurate measurements of respiration. Accurate calibration of the oxygen sensor depends on (''1'') equilibration of the incubation medium with air oxygen partial pressure at the temperature defined by the experimenter; (''2'') zero oxygen calibration; (''3'') high stability of the POS signal tested for sufficiently long periods of time; (''4'') linearity of signal output with oxygen pressure in the range between oxygen saturation and zero oxygen pressure; and (''5'') accurate oxygen solubility for aqueous solutions for the conversion of partial oxygen pressure into oxygen concentration. The standard oxygen calibration procedure is described below for high-resolution respirometry with the calibration routine using instrumental calibration DL-Protocols in [[DatLab]].[[DatLab]].)