Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Search results

From Bioblast
Results 21 – 36 of 37
Advanced search

Search in namespaces:

  
  
  
  
  
  
  
  
  
  
  
  
  
  • ...AmplexRed_H2O2-production#Calibration_with_H2O2|H<sub>2</sub>O<sub>2</sub> calibration steps]] are done during the experiment. The measurement is carried out in M
    6 KB (864 words) - 23:56, 12 April 2021
  • ...titration (SUIT) protocol with substrates for fatty acid oxidation (FAO), NADH-pathway (N), and succinate-pathway (S). Superimposed oxygraph traces (mass- ...nsor calibration), calibration of the sensor response time (dynamic sensor calibration), and evaluation of [[MiPNet14.06 Instrumental O2 background |instrumental
    8 KB (1,056 words) - 10:11, 23 May 2022
  • ...ce for FluoRespirometry due to the highest stability of the sensitivity or calibration constant observed in experiments over periods of up to 2 h. ...synthesis, MitoFit 2021 AmR-O2, MitoFit 2021 Tissue normoxia, MitoFit 2022 NADH, MitoFit 2022 ROS review, H2O2, O2k-Demo
    3 KB (453 words) - 12:33, 25 October 2023
  • ..., TPP<sup>+</sup>-Module • mt-membrane potential, pH-Module, NO, Q-Module, NADH-Module, PB-Module ...Volume-Calibration Ring sV]] || [[Volume-Calibration Ring]] [[Image:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]]
    12 KB (1,709 words) - 13:03, 5 February 2024
  • ...chnical service and the instrumental quality controls 1 ([[MiPNet06.03 POS-calibration-SOP |O2 sensor test]]) and 2 ([[MiPNet14.06 Instrumental O2 background |O2k ...all-in-one''' provides advanced training on detection of Coenzyme Q and/or NADH redox state, always in combination with high-resolution respirometry. The P
    5 KB (667 words) - 14:56, 11 July 2022
  • ::::* Final concentration: 0.2-1 µM. Stepwise titration for calibration. ::::* Final concentration: 0.5-2 µM. Stepwise titration for calibration.
    17 KB (2,405 words) - 07:29, 5 April 2024
  • |''' Background H<sub>2</sub>O<sub>2</sub> calibration in the Amplex® UltraRed (AmR) assay:'''<br> A background H<sub>2</sub>O<sub>2</sub> calibration is performed before addition of sample. This is required for (''1'') calcul
    21 KB (2,889 words) - 13:31, 19 January 2021
  • ...ment (check by initial and final H<sub>2</sub>O<sub>2</sub> titrations for calibration). The ''final'' concentration of AmR becomes diminished during an experimen == Calibration with H<sub>2</sub>O<sub>2</sub> ==
    35 KB (5,265 words) - 15:10, 25 April 2024
  • ::::» NADH-linked or N-pathways (CI-entry into Q); succinate-linked or S-pathway (CII- ::::» Calibration of polarographic oxygen sensors and oxygen concentration in respiration med
    12 KB (1,521 words) - 14:23, 15 May 2023
  • ...rch questions. Furthermore, this workshop covers interpretation as well as calibration and instrumental service. :::::» Chapters 4-5: NADH-linked pathways through Complex CI and S-pathway through Complex CII (estim
    7 KB (948 words) - 15:29, 13 May 2024
  • ...rch questions. Furthermore, this workshop covers interpretation as well as calibration and instrumental service. ...3-10-06_Grings_IOC_162_Q_NADH_PB.pdf The NextGen O2k all-in-one: Q-Module, NADH-Module, and PhotoBiology-Module]
    14 KB (2,037 words) - 16:11, 2 November 2023
  • ...rch questions. Furthermore, this workshop covers interpretation as well as calibration and instrumental service. :::::» Chapters 4-5: NADH-linked pathways through Complex CI and S-pathway through Complex CII (estim
    9 KB (1,271 words) - 14:52, 13 May 2024
  • ...sub>2</sub> calibrations throughout the measurement. After the initial AmR calibration, ensure that the sensitivity is within the recommended range.'''<br> ...ect ''F''<sub>M</sub> needs to be entered in DatLab when performing an air calibration. <br>
    29 KB (4,269 words) - 09:03, 13 May 2024
  • Yes, oxygen signals obtained after proper calibration are independent of the gain setting, and can therefore be grouped together |''' Background H<sub>2</sub>O<sub>2</sub> calibration in the Amplex® UltraRed (AmR) assay:'''<br>
    126 KB (17,785 words) - 08:55, 13 August 2021
  • |'''The NADH-Module of the NextGen-O2k incorporates a UV light and NADH-Sensors to enable the evaluation of the redox state of the NAD(P)H-pool'''< ...nd if linear, the absolute mtMP can be calculated. TPP<sup>+</sup> enables calibration for measurement of mtMP.<br>
    85 KB (11,819 words) - 14:18, 10 January 2022
  • ...k-sV-Module|O2k-sV-Module]]'''«, »'''[[MiPNet06.03 POS-calibration-SOP|POS calibration-SOP]]'''«<br> |''' Barometric pressure displaying as 0 kPa in the O2 calibration window? '''<br>
    80 KB (11,165 words) - 09:37, 8 January 2024

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)