Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Oxycaloric equivalent"

From Bioblast
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|abbr=Delta<sub>k</sub>''H''<sub>O2</sub>
|abbr=Delta<sub>k</sub>''H''<sub>O2</sub>
|description=The '''oxycaloric equivalent''' is the theoretically derived enthalpy change of the oxidative catabolic reactions per amount of oxygen respired, Delta<sub>k</sub>''H''<sub>O2</sub>, ranging from -430 to -480 kJ/mol O<sub>2</sub>. Experimentally determined [[Calorespirometric ratio|calorimetric/respirometric (CR) ratios]] more exothermic than the oxycaloric equivalent of -480 kJ/mol indicate the simultaneous involvement of aerobic and anaerobic mechanisms of energy metabolism.
|description=The '''oxycaloric equivalent''' is the theoretically derived enthalpy change of the oxidative catabolic reactions per amount of oxygen respired, Delta<sub>k</sub>''H''<sub>O2</sub>, ranging from -430 to -480 kJ/mol O<sub>2</sub>. The oxycaloric equivalent is used in [[indirect calorimetry]] to calculate the theoretically expected metabolic heat flux from the respirometrically measured metabolic oxygen flux.Β  [[Calorespirometric ratio|calorimetric/respirometric ratios]] (CR ratios; heat/oxygen flux ratios) are experimentally determined by [[calorespirometry]].Β  A CR ratio more exothermic than the oxycaloric equivalent of -480 kJ/mol indicates the simultaneous involvement of aerobic and anaerobic mechanisms of energy metabolism.
|info=[[Gnaiger_1983_JEZ]], [[Gnaiger_1990_BBA]]
|info=[[Gnaiger_1983_JEZ]], [[Gnaiger_1990_BBA]]
}}
}}
{{MitoPedia topics}}
{{MitoPedia topics}}

Revision as of 12:40, 6 November 2011


high-resolution terminology - matching measurements at high-resolution


Oxycaloric equivalent

Description

The oxycaloric equivalent is the theoretically derived enthalpy change of the oxidative catabolic reactions per amount of oxygen respired, DeltakHO2, ranging from -430 to -480 kJ/mol O2. The oxycaloric equivalent is used in indirect calorimetry to calculate the theoretically expected metabolic heat flux from the respirometrically measured metabolic oxygen flux. calorimetric/respirometric ratios (CR ratios; heat/oxygen flux ratios) are experimentally determined by calorespirometry. A CR ratio more exothermic than the oxycaloric equivalent of -480 kJ/mol indicates the simultaneous involvement of aerobic and anaerobic mechanisms of energy metabolism.

Abbreviation: DeltakHO2

Reference: Gnaiger_1983_JEZ, Gnaiger_1990_BBA