|description=[[Image:Oxia.png|180px|right]]'''Oxia - HyperOxia to HypOxia''': The Oxia generates gaseous oxygen and hydrogen by electrolysis of water using a proton exchange membrane (PEM). | |description=[[Image:Oxia.png|180px|right]]'''Oxia - HyperOxia to HypOxia''': The Oxia generates gaseous [[oxygen]] and [[hydrogen]] by electrolysis of water using a proton exchange membrane (PEM). O<sub>2</sub> and H<sub>2</sub> gas can be used to control the O<sub>2</sub> regime in the Oroboros O2k. Low oxygen concentrations (<50 ยตM) are used to mimic tissue [[normoxia]] or [[hypoxia]]. Hyperoxic conditions above air saturation (250-600 ยตM O<sub>2</sub>) are routinely used for high-resolution respirometry of [[permeabilized muscle fibers]] or to induce oxidative stress in cells and [[mitochondrial preparations]]. | ||
|info= [https://www.oroboros.at/index.php/product/oxia/'''Product details and purchasing information'''] | |info= [https://www.oroboros.at/index.php/product/oxia/'''Product details and purchasing information'''] | ||
}} | }} | ||
== Additional resources == | == Additional resources == | ||
::ยป [[MiPNet26.14 Oxia]] | ::::ยป [[MiPNet26.14 Oxia]] | ||
ย | |||
::::ยป [[Oxygen]] | |||
::::ยป [[Hydrogen]] ย | |||
{{MitoPedia O2k and high-resolution respirometry | {{MitoPedia O2k and high-resolution respirometry | ||
|mitopedia O2k and high-resolution respirometry=O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | |mitopedia O2k and high-resolution respirometry=O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | ||
}} | }} |
Revision as of 15:23, 24 December 2021
Oxia |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Oxia - HyperOxia to HypOxia: The Oxia generates gaseous oxygen and hydrogen by electrolysis of water using a proton exchange membrane (PEM). O2 and H2 gas can be used to control the O2 regime in the Oroboros O2k. Low oxygen concentrations (<50 ยตM) are used to mimic tissue normoxia or hypoxia. Hyperoxic conditions above air saturation (250-600 ยตM O2) are routinely used for high-resolution respirometry of permeabilized muscle fibers or to induce oxidative stress in cells and mitochondrial preparations.
Reference: Product details and purchasing information
Additional resources
MitoPedia O2k and high-resolution respirometry: O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry