O2k-Titration Set: Difference between revisions

From Bioblast
No edit summary
No edit summary
Β 
(77 intermediate revisions by 15 users not shown)
Line 1: Line 1:
{{Mainpage orobopedia}}
{{Technical support}}
{{Product
__TOC__
|description=The '''Titration Set''' consists of 6x 10 Β΅l, 6x 25 Β΅l, and 2x 50 Β΅l Hamilton glass syringes, and 3 spare plungers for the 10 Β΅l syringes. It is a basic HRR-Accessory included in the [[O2k-Core]] Unit.
{{MitoPedia without banner
|product id=20820-01
|abbr=
|product type=O2k, O2k-Module, O2k-Core, Microsyringe, Catalogue
|description=[[Image:O2k-Titration Set.JPG|right|180px]] The '''O2k-Titration Set''' consists of Hamilton microsyringes (6 x 10 mm<sup>3</sup> and 3 spare plungers, 6 x 25 mm<sup>3</sup>, 1 x 50 mm<sup>3</sup>, 1 x 100 mm<sup>3</sup>, 1 x 500 mm<sup>3</sup>; fixed needles with rounded tips), provided in the [[Syringe Storage Box]] with [[Syringe Labels]], a set of two [[Syringe Racks]] with [[Syringe Collars]], and a set of two [[Tube Racks]].
|info=[[MiPNet09.12 O2k-Titrations]]
Β 
|product image=[[File:Hamilton Syringes for Manual Titration.jpg|right|180px|link=]]
|info= [https://www.oroboros.at/index.php/product/o2k-titration-set/ '''Product details and purchasing information''']
}}
}}


== The '''Titration Set''' ''consists of'' ==
== Additional resources ==
:::: Β»[[MiPNet09.12 O2k-Titrations]] </br>
:::: Β»[[MiPNet19.14 SOP Hamilton microsyringes]]


:6 [[Microsyringe\10 mm3 51/0.13 mm]] 10 mm<sup>3</sup>
:6 [[Microsyringe\25 mm3 51/0.15 mm]] 25 mm<sup>3</sup>
:2 [[Microsyringe\50 mm3 51/0.15 mm]] 50 mm<sup>3</sup>
:3 [[Plunger\10 mm3]] for 10 mm<sup>3</sup> syringe


== Note: Titration of chemicals in respirometry ==
:::: Overshoots or short interruptions of the flux after the injection of chemicals do not have a meaning in respirometric measurements. A disturbance of the signal is only observed due to the injected chemical and does not represent mitochondrial respiration. With the addition of a chemical solved in ethanol a little bit of oxygen is always introduced, since ethanol has higher oxygen solubility than water.


== Handling of the syringes ==
::::Β  After a titration, it is common to observe liquid accumulated on top of the stopper receptacle. When this happens, we recommend removing this excess of liquid as it can lead to O<sub>2</sub> backdiffusion into the chamber. For this, we recommend using the [[ISS]], placing the tip close to the capillary, but not directly on top of it.
* separate inhibitors from substrates
Β 
* rinse the outside with water immediately after use
=== Further information ===
* at the start of a day: rinse the outside with the pure solvent and wash the syringes 3 times with the pure solvent
:::* Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
* rinse with pure solvent before use
:::* Hamilton microsyringes are specifically produced for O2k-titrations and can be ordered directly from Oroboros Instruments to assure exact fitting with the O2k-Stopper and O2k-Chamber dimensions.
* between two runs during the day: rinse the outside with water
:::* Visit also: [http://www.hamiltoncompany.com/products/syringes-and-needles Hamilton].
* at the end of a day: wash 3 x with last used solvent, rinse 3 x with EtOH 100 %
:::* Eliminate rough edges with 3Mβ„’ Wetordryβ„’ Paper Sheet P1000 by gentle rubbing.
* storage: ethanol 100% (short), dry (longtime)
:::* Use a cleaning wire for the needle. If a syringe is clogged , sometimes it is also helpful to fill it from the back with EtOH or H<sub>2</sub>O and try to press the plunger gently down.
Β 
Β 
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}

Latest revision as of 17:46, 11 October 2022


                  


O2k-Open Support

O2k-Titration Set



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

O2k-Titration Set.JPG

The O2k-Titration Set consists of Hamilton microsyringes (6 x 10 mm3 and 3 spare plungers, 6 x 25 mm3, 1 x 50 mm3, 1 x 100 mm3, 1 x 500 mm3; fixed needles with rounded tips), provided in the Syringe Storage Box with Syringe Labels, a set of two Syringe Racks with Syringe Collars, and a set of two Tube Racks.


Reference: Product details and purchasing information


Additional resources

Β»MiPNet09.12 O2k-Titrations
Β»MiPNet19.14 SOP Hamilton microsyringes


Note: Titration of chemicals in respirometry

Overshoots or short interruptions of the flux after the injection of chemicals do not have a meaning in respirometric measurements. A disturbance of the signal is only observed due to the injected chemical and does not represent mitochondrial respiration. With the addition of a chemical solved in ethanol a little bit of oxygen is always introduced, since ethanol has higher oxygen solubility than water.
After a titration, it is common to observe liquid accumulated on top of the stopper receptacle. When this happens, we recommend removing this excess of liquid as it can lead to O2 backdiffusion into the chamber. For this, we recommend using the ISS, placing the tip close to the capillary, but not directly on top of it.

Further information

  • Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
  • Hamilton microsyringes are specifically produced for O2k-titrations and can be ordered directly from Oroboros Instruments to assure exact fitting with the O2k-Stopper and O2k-Chamber dimensions.
  • Visit also: Hamilton.
  • Eliminate rough edges with 3Mβ„’ Wetordryβ„’ Paper Sheet P1000 by gentle rubbing.
  • Use a cleaning wire for the needle. If a syringe is clogged , sometimes it is also helpful to fill it from the back with EtOH or H2O and try to press the plunger gently down.


MitoPedia O2k and high-resolution respirometry: O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry 