Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet24.14 O2k-sV-Module manual"

From Bioblast
Line 1: Line 1:
{{OROBOROS header page name}}
{{Publication
{{Publication
|title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] O2k-sV-Module manual.
|title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] O2k-sV-Module manual.
Line 12: Line 11:


:» Product:[[O2k-sV-Module]], [[Oroboros O2k-Catalogue]]
:» Product:[[O2k-sV-Module]], [[Oroboros O2k-Catalogue]]
|keywords=
|mipnetlab=AT_Innsbruck_Oroboros
|mipnetlab=AT_Innsbruck_Oroboros
}}
}}
{{Labeling
{{Labeling
|area=Instruments;methods
|area=Instruments;methods
|instruments=Oxygraph-2k, O2k-Fluorometer, O2k-Manual
|instruments=Oxygraph-2k, O2k-Fluorometer, O2k-Manual
|additional= DatLab,  
|additional=DatLab,
}}
}}
{{OROBOROS header page name}}






{{Technical support integrated}}
{{Technical support integrated}}

Revision as of 13:43, 23 October 2019

Publications in the MiPMap
O2k-Manual
O2k-sV-Module manual.

» Bioblast pdf »[ Versions]

Oroboros (2019-10-23) Mitochondr Physiol Network

Abstract: Passrugger M, Gallée L, Krumschnabel G, Tindle-Solomon L, Gnaiger E, Doerrier C (2019) O2k-sV-Module manual. Mitochondr Physiol Network 24.14(01):1-8.

O2k-Manual: The O2k-sV-Module is a modular extension of the O2k specifically designed to perform high-resolution respirometry with reduced amount of biological sample and chemicals, leading to an overall decrease of running costs and expanding the application scope of samples with limited availability. The O2k-sV-Module exchanges the standard 2 mL O2k-Chamber for a smaller operation volume of 0.5 mL. The O2k-sV-Module is compatible with all O2k-Series, however it cannot be used for simultaneous measurement of multiple parameters in the O2k-FluoRespirometer or in combination with the O2k-MultiSensor Modules. The use of O2k-sV-Module is recommended at normoxic range, in a narrow experimental range of oxygen concentration near air saturation to reduce technical problems of oxygen diffusion and instrumental O2 background.

» Product:O2k-sV-Module, Oroboros O2k-Catalogue


O2k-Network Lab: AT_Innsbruck_Oroboros


Labels: MiParea: Instruments;methods 





HRR: Oxygraph-2k, O2k-Fluorometer, O2k-Manual 

DatLab 

                



MiPNet24.14 O2k-sV-Module manual





Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support