Line 1: | Line 1: | ||
{{Publication | {{Publication | ||
|title=Gnaiger E (2003) Service of the polarographic oxygen sensor OroboPOS. Mitochondr Physiol Network 08.04. | |title=Gnaiger E (2003) Service of the polarographic oxygen sensor OroboPOS. Mitochondr Physiol Network 08.04. | ||
|info='''Open Access - [ | |info=[[Media:MiPNet08.04 POS-Service.pdf|'''Open Access-MiPNet08.04.pdf''']]; [http://www.bioblast.at/index.php/File:MiPNet08.04_POS-Service.pdf Versions] [[Image:O2k-Manual.jpg|right|150px|link=http://www.oroboros.at/?o2k-manual|O2k-Manual contents]] | ||
|authors=OROBOROS | |authors=OROBOROS | ||
|year=2003 | |year=2003 | ||
|journal=Mitochondr Physiol Network | |journal=Mitochondr Physiol Network | ||
|abstract= '''O2k-Manual Chapter B''' | |||
<ins>Frequency of POS-Service:</ins> | |||
Instead of a fixed interval we suggest to follow an [[Instrumental quality assurance]] plan and to perform a POS service only when the conditions listed in this manual (see above for link to pdf) are met. | |||
:>> O2k-Manual:[http://www.oroboros.at/?o2k-manualย Overall contents] | |||
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]] | |||
|keywords=HRR | |keywords=HRR | ||
|mipnetlab=AT_Innsbruck_OROBOROS | |mipnetlab=AT_Innsbruck_OROBOROS | ||
}} | }} | ||
{{Labeling | {{Labeling | ||
|area=Respiration, Instruments;methods | |area=Respiration, Instruments;methods | ||
Line 15: | Line 22: | ||
}} | }} | ||
== | == Further information == | ||
ย | :>> [http://www.oroboros.at/?o2k-pos-service MiPNet08.04] | ||
:>> MiPNet06.04 is integrated in MiPNet08.04 POS-Service. | |||
* Version 10: 2012-10-24 | * Version 10: 2012-10-24 | ||
* Version 1: 2003 | * Version 1: 2003 | ||
ย | |||
[[Category:OroboPedia]] | [[Category:OroboPedia]] |
Revision as of 09:00, 17 October 2013
Gnaiger E (2003) Service of the polarographic oxygen sensor OroboPOS. Mitochondr Physiol Network 08.04. |
ยป Open Access-MiPNet08.04.pdf; Versions
OROBOROS (2003) Mitochondr Physiol Network
Abstract: O2k-Manual Chapter B
Frequency of POS-Service: Instead of a fixed interval we suggest to follow an Instrumental quality assurance plan and to perform a POS service only when the conditions listed in this manual (see above for link to pdf) are met.
- >> O2k-Manual:Overall contents
- >> Product: OROBOROS Oxygraph-2k, O2k-Catalogue
โข Keywords: HRR
โข O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels: MiParea: Respiration, Instruments;methods
HRR: Oxygraph-2k, O2k-Manual
Further information
- >> MiPNet08.04
- >> MiPNet06.04 is integrated in MiPNet08.04 POS-Service.
- Version 10: 2012-10-24
- Version 1: 2003