Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet18.05 Amplex-Mouse-heart"

From Bioblast
Line 1: Line 1:
{{Publication
{{Publication
|title=Eigentler A, Fontana-Ayoub M, Gnaiger E (2013) O2k-Fluorometry: HRR and H<sub>2</sub>O<sub>2</Sub> production in mouse cardiac tissue homogenate. Mitochondr Physiol Network 18.05.
|title=Eigentler A, Fontana-Ayoub M, Gnaiger E (2013) O2k-Fluorometry: HRR and H<sub>2</sub>O<sub>2</Sub> production in mouse cardiac tissue homogenate. Mitochondr Physiol Network 18.05.
|info='''Bioblast [[File:MiPNet18.05_Amplex-Mouse-heart.pdf]]'''
|info=[[Media:MiPNet18.05_Amplex-Mouse-heart.pdf|'''Open Access-MiPNet18.05.pdf''']]; [http://www.bioblast.at/index.php/File:MiPNet18.05_Amplex-Mouse-heart.pdf Versions] [[Image:O2k-Protocols.jpg|right|150px|link=http://www.oroboros.at/?o2k-protocols|O2k-Protocols contents]]
 
|authors=OROBOROS
|authors=OROBOROS
|year=2013
|year=2013
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract=The [[O2k-Fluorescence LED2-Module]] is an extension of the OROBOROS Oxygraph-2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H<sub>2</sub>O<sub>2</Sub> production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H<sub>2</sub>O<sub>2</Sub> production.
|abstract='''O2k-Protocol for : HRR and H<sub>2</sub>O<sub>2</sub> production in mouse cardiac tissue homogenate.'''
 
The [[O2k-Fluorescence LED2-Module]] is an extension of the OROBOROS Oxygraph-2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H<sub>2</sub>O<sub>2</Sub> production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H<sub>2</sub>O<sub>2</Sub> production.
:>> O2k-Protocols:[http://www.oroboros.at/?o2k-protocols Overall contents]
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]]
 
|mipnetlab=AT Innsbruck Gnaiger E, AT Innsbruck OROBOROS, AT Innsbruck MitoCom
|mipnetlab=AT Innsbruck Gnaiger E, AT Innsbruck OROBOROS, AT Innsbruck MitoCom
|link=
|link=

Revision as of 13:36, 18 October 2013

Publications in the MiPMap
Eigentler A, Fontana-Ayoub M, Gnaiger E (2013) O2k-Fluorometry: HRR and H2O2 production in mouse cardiac tissue homogenate. Mitochondr Physiol Network 18.05.

» Open Access-MiPNet18.05.pdf; Versions

O2k-Protocols contents

OROBOROS (2013) Mitochondr Physiol Network

Abstract: O2k-Protocol for : HRR and H2O2 production in mouse cardiac tissue homogenate.

The O2k-Fluorescence LED2-Module is an extension of the OROBOROS Oxygraph-2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H2O2 production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H2O2 production.

>> O2k-Protocols:Overall contents
>> Product: OROBOROS Oxygraph-2k, O2k-Catalogue


O2k-Network Lab: AT Innsbruck Gnaiger E, AT Innsbruck OROBOROS, AT Innsbruck MitoCom


Labels: MiParea: Respiration 


Organism: Mouse  Tissue;cell: Heart  Preparation: Homogenate 

Regulation: Cyt c  Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, Fluorometry"Fluorometry" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

Label