|journal=Mitochondr Physiol Network
|abstract=The [[O2k-Fluorescence LED2-Module]] is an extension of the OROBOROS Oxygraph-2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H<sub>2</sub>O<sub>2</Sub> production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H<sub>2</sub>O<sub>2</Sub> production.  
|abstract=The [[O2k-Fluorescence LED2-Module]] is an extension of the OROBOROS Oxygraph-2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H<sub>2</sub>O<sub>2</Sub> production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H<sub>2</sub>O<sub>2</Sub> production.
|mipnetlab=AT Innsbruck Gnaiger E, AT Innsbruck OROBOROS, AT Innsbruck MitoCom
|link=
|link=
}}
}}
{{Labeling
{{Labeling
|area=Respiration
|area=Respiration
|organism=Saccharomyces cerevisiae
|organism=Mouse
|taxonomic group=Fungi
|tissues=Heart
|preparations=Intact cells
|preparations=Homogenate
|topics=O2, Uncoupler
|topics=Cyt c
|couplingstates=ROUTINE, ETS
|couplingstates=LEAK, OXPHOS, ETS
|substratestates=CI, CII, CI+II
|instruments=Oxygraph-2k, Fluorometry, Protocol
|instruments=Oxygraph-2k, Fluorometry, Protocol
|additional=Label
|additional=Label
|link=
}}
}}

Revision as of 10:51, 6 October 2013

Publications in the MiPMap
Eigentler A, Fontana-Ayoub M, Gnaiger E (2013) O2k-Fluorometry: HRR and H2O2 production in mouse cardiac tissue homogenate. Mitochondr Physiol Network 18.05.

» Bioblast Access - File:MiPNet18.05 Amplex-Mouse-heart.pdf

OROBOROS (2013) Mitochondr Physiol Network

Abstract: The O2k-Fluorescence LED2-Module is an extension of the OROBOROS Oxygraph-2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H2O2 production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H2O2 production.


O2k-Network Lab: AT Innsbruck Gnaiger E, AT Innsbruck OROBOROS, AT Innsbruck MitoCom


Labels: MiParea: Respiration 


Organism: Mouse  Tissue;cell: Heart  Preparation: Homogenate 

Regulation: Cyt c  Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, Fluorometry"Fluorometry" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

Label