|title=Eigentler A, Fontana-Ayoub M, Gnaiger E. PBI-Shredder_Mouse-heart-brain-liver: Tissue Homogenates for Diagnosis of Mitochondrial Respiratory Function: Mouse Heart, Brain and Liver. Mitochondr Physiol Network 17.15.
|title=Eigentler A, Fontana-Ayoub M, Gnaiger E. Tissue homogenates for diagnosis of mitochondrial respiratory function: Mouse heart, brain and liver. Mitochondr Physiol Network 17.15.
|info=[http://oroboros.at/index.php?id=pbi-shredder-manual MiPNet17.15. Open Access], [[PBI-Shredder HRR-Set]]
|info=[http://www.oroboros.at/?homogenate MiPNet17.15. Open Access], [[PBI-Shredder HRR-Set]]
|authors=Eigentler A, Fontana-Ayoub M, Gnaiger E
|authors=Eigentler A, Fontana-Ayoub M, Gnaiger E
|year=*
|year=*
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract=A high-quality preparation of tissue homogenate may represent an optimum compromise for a variety of respirometric and fluorometric studies. These considerations provided the rationale for initiating a study with the PBI-Shredder, an auxiliary HRR-Tool providing a standardized approach to prepare homogenates of various tissues (e.g. heart, liver, brain) with high reproducibility of mitochondrial yield and mitochondrial function as evaluated with HRR.
|abstract=A high-quality preparation of tissue homogenate may represent an optimum compromise for a variety of respirometric and fluorometric studies. These considerations provided the rationale for initiating a study with the PBI-Shredder, an auxiliary HRR-Tool providing a standardized approach to prepare homogenates of various tissues (e.g. heart, liver, brain) with high reproducibility of 100% mitochondrial yield and mitochondrial function as evaluated with HRR.
|keywords=Tissue homogenate, shredder
|keywords=Tissue homogenate, shredder
|mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom
|mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom
Line 12: Line 12:
{{Labeling
{{Labeling
|instruments=Oxygraph-2k, O2k-Manual, Protocol, MiPNet-Publication
|instruments=Oxygraph-2k, O2k-Manual, Protocol, MiPNet-Publication
|organism=Mouse
|tissues=Heart, Nervous system, Liver
|preparations=Homogenate
|preparations=Homogenate
|couplingstates=LEAK, OXPHOS, ETS
|substratestates=CI, CII, CI+II
|additional=mt-Preparation
|additional=mt-Preparation
|articletype=Protocol; Manual, MiPNet-online Publication
|articletype=Protocol; Manual, MiPNet-online Publication
}}
}}
[[Category:OroboPedia]]
[[Category:OroboPedia]]

Revision as of 17:36, 23 June 2013

Publications in the MiPMap
Eigentler A, Fontana-Ayoub M, Gnaiger E. Tissue homogenates for diagnosis of mitochondrial respiratory function: Mouse heart, brain and liver. Mitochondr Physiol Network 17.15.

Β» MiPNet17.15. Open Access, PBI-Shredder HRR-Set

Eigentler A, Fontana-Ayoub M, Gnaiger E (

) Mitochondr Physiol Network

Abstract: A high-quality preparation of tissue homogenate may represent an optimum compromise for a variety of respirometric and fluorometric studies. These considerations provided the rationale for initiating a study with the PBI-Shredder, an auxiliary HRR-Tool providing a standardized approach to prepare homogenates of various tissues (e.g. heart, liver, brain) with high reproducibility of 100% mitochondrial yield and mitochondrial function as evaluated with HRR. β€’ Keywords: Tissue homogenate, shredder

β€’ O2k-Network Lab: AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom


Labels:


Organism: Mouse  Tissue;cell: Heart, Nervous system, Liver  Preparation: Homogenate 


Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

mt-Preparation