Difference between revisions of "MiPNet15.08 TPP electrode"
From Bioblast
Line 1: | Line 1: | ||
{{Publication | {{Publication | ||
|title=[[Image:O2k-Protocols.jpg|right|80px|link=O2k-Protocols|O2k-Protocols]] Ion selective electrode for TPP<sup>+</sup> and high-resolution respirometry. | |title=[[Image:O2k-Protocols.jpg|right|80px|link=O2k-Protocols|O2k-Protocols]] Ion selective electrode for TPP<sup>+</sup> and high-resolution respirometry. | ||
|info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/c/c5/MiPNet15.08_TPP-electrode.pdf |Bioblast pdf]] | |info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/c/c5/MiPNet15.08_TPP-electrode.pdf |Bioblast pdf]] »[http://www.bioblast.at/index.php/File:MiPNet15.08_TPP-electrode.pdf Versions] | ||
|authors=Oroboros | |authors=Oroboros | ||
|year=2011-12-11 | |year=2011-12-11 | ||
|journal=Mitochondr Physiol Network | |journal=Mitochondr Physiol Network | ||
|abstract='''Sumbalova Z, Fasching M, Gnaiger E (2011) Ion selective electrode for TPP<sup>+</sup> and high-resolution respirometry. Mitochondr Physiol Network 15.8.''' | |abstract='''Sumbalova Z, Fasching M, Gnaiger E (2011) Ion selective electrode for TPP<sup>+</sup> and high-resolution respirometry. Mitochondr Physiol Network 15.8.''' | ||
Tetraphenylphosphonium (TPP<sup>+</sup>) accumulates in the mitochondrial matrix as a function of the [[mitochondrial membrane potential]]. The TPP<sup>+</sup> electrode is an ion selective electrode (ISE). The voltage signal [V] is linearly dependent on the logarithm of the free concentration [TPP<sup>+</sup>]. | Tetraphenylphosphonium (TPP<sup>+</sup>) accumulates in the mitochondrial matrix as a function of the [[mitochondrial membrane potential]]. The TPP<sup>+</sup> electrode is an ion selective electrode (ISE). The voltage signal [V] is linearly dependent on the logarithm of the free concentration [TPP<sup>+</sup>]. |
Revision as of 10:16, 11 January 2018
Ion selective electrode for TPP+ and high-resolution respirometry. |
» »Versions
Oroboros (2011-12-11) Mitochondr Physiol Network
Abstract: Sumbalova Z, Fasching M, Gnaiger E (2011) Ion selective electrode for TPP+ and high-resolution respirometry. Mitochondr Physiol Network 15.8.
Tetraphenylphosphonium (TPP+) accumulates in the mitochondrial matrix as a function of the mitochondrial membrane potential. The TPP+ electrode is an ion selective electrode (ISE). The voltage signal [V] is linearly dependent on the logarithm of the free concentration [TPP+].
- » Poster
- » O2k-Protocols
- » Product: Oroboros O2k, ISE, O2k-Catalogue
• Keywords: O2k-MultiSensor System
• O2k-Network Lab: AT_Innsbruck_Oroboros
Labels: MiParea: Respiration, Instruments;methods
HRR: Oxygraph-2k, TPP, O2k-Protocol
O2k-Demo, O2k-MultiSensor