MiPNet15.03 O2k-MultiSensor-ISE: Difference between revisions
m (moved MiPNet15.03 to MiPNet15.03 MultiSensor-ISE) |
No edit summary |
||
Line 3: | Line 3: | ||
|authors=Fasching M, Gnaiger E | |authors=Fasching M, Gnaiger E | ||
|year=* | |year=* | ||
|journal=Mitochondr. Physiol. Network | |||
|mipnetlab=AT_Innsbruck_Oroboros | |mipnetlab=AT_Innsbruck_Oroboros | ||
|abstract=The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system. | |||
|keywords=HRR-MultiS | |keywords=HRR-MultiS | ||
|info=[http://www.oroboros.at/index.php?id=o2k-multisensor MiPNet15.03] | |info=[http://www.oroboros.at/index.php?id=o2k-multisensor MiPNet15.03] | ||
Line 11: | Line 13: | ||
|articletype=Protocol; Manual, MiPNet-online Publication | |articletype=Protocol; Manual, MiPNet-online Publication | ||
}} | }} | ||
[[Category:OroboroPedia]] |
Revision as of 16:18, 20 October 2010
Fasching M, Gnaiger E. O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr. Physiol. Network 15.03. |
ยป MiPNet15.03
) Mitochondr. Physiol. Network
Abstract: The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system. โข Keywords: HRR-MultiS
โข O2k-Network Lab: AT_Innsbruck_Oroboros
Labels:
HRR: Oxygraph-2k, TIP2k, MultiSensor pH; TPP; NO"MultiSensor pH; TPP; NO" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., DatLab Software; Separate Application"DatLab Software; Separate Application" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., Method"Method" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.