Line 8: Line 8:


Methodological and conceptual features of highresolution respirometry are illustrated in an experiment with cultured, suspended cells in the OROBOROS
Methodological and conceptual features of highresolution respirometry are illustrated in an experiment with cultured, suspended cells in the OROBOROS
Oxygraph-2k (O2k). The experiment demonstrates manual titrations of inhibitors, and automatic titrations of an uncoupler using the electronic Titration-Injection microPump TIP2k. Application of the DatLab 4.3 (upgraded) software is shown for instrumental control (O2k and TIP2k), and on-line data analysis. The following guideline describes the experiment in the form of a laboratory protocol, complementary to the relevant sections of the Oxygraph-2k Manual. The experiments were carried out by participants of an O2k-Course on high-resolution respirometry in April 2005 (IOC30; Schröcken, Austria).
Oxygraph-2k (O2k). The experiment demonstrates manual titrations [http://bioblast.at/images/e/ef/MiPNet09.12_O2k-Titrations.pdf] of inhibitors, and automatic titrations of an uncoupler using the electronic Titration-Injection microPump TIP2k [http://www.bioblast.at/images/8/8e/MiPNet04.05_Titration-Injection.pdf]. Application of the DatLab 4.3 (upgraded) software is shown for instrumental control (O2k and TIP2k), and on-line data analysis [http://www.bioblast.at/images/2/28/MiPNet12.09_O2FluxAnalysis.pdf]. The following guideline describes the experiment in the form of a laboratory protocol, complementary to the relevant sections of the Oxygraph-2k Manual. The experiments were carried out by participants of an O2k-Course on high-resolution respirometry in April 2005 (IOC30; Schröcken, Austria).
:>> O2k-Protocols:[http://www.oroboros.at/?o2k-protocols Overall contents]
:>> O2k-Protocols:[http://www.oroboros.at/?o2k-protocols Overall contents]
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]]
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]]
|mipnetlab=AT_Innsbruck_OROBOROS
|mipnetlab=AT_Innsbruck_OROBOROS
}}
}}
{{Labeling
{{Labeling
|area=Respiration, Instruments;methods
|area=Respiration, Instruments;methods
Line 26: Line 24:
|additional=O2k-Demo
|additional=O2k-Demo
}}
}}
== Further information ==
== Further information ==
:>> [http://www.oroboros.at/?protocols_cell_hrr MiPNet10.04]
:>> [http://www.oroboros.at/?protocols_cell_hrr MiPNet10.04]

Revision as of 10:33, 29 November 2013

Publications in the MiPMap
Garedew A, Haffner B, Huetter E, Gnaiger E (2005) An experiment with high-resolution respirometry: Phosphorylation control in cell respiration. Mitochondr Physiol Network 10.04.

» Open Access-MiPNet10.04.pdf; Versions

O2k-Protocols contents

OROBOROS (2005) Mitochondr Physiol Network

Abstract: O2k-Protocol for Phosphorylation Control in Cell Respiration

Methodological and conceptual features of highresolution respirometry are illustrated in an experiment with cultured, suspended cells in the OROBOROS Oxygraph-2k (O2k). The experiment demonstrates manual titrations [1] of inhibitors, and automatic titrations of an uncoupler using the electronic Titration-Injection microPump TIP2k [2]. Application of the DatLab 4.3 (upgraded) software is shown for instrumental control (O2k and TIP2k), and on-line data analysis [3]. The following guideline describes the experiment in the form of a laboratory protocol, complementary to the relevant sections of the Oxygraph-2k Manual. The experiments were carried out by participants of an O2k-Course on high-resolution respirometry in April 2005 (IOC30; Schröcken, Austria).

>> O2k-Protocols:Overall contents
>> Product: OROBOROS Oxygraph-2k, O2k-Catalogue


O2k-Network Lab: AT_Innsbruck_OROBOROS


Labels: MiParea: Respiration, Instruments;methods 


Organism: Mouse  Tissue;cell: Blood cells  Preparation: Intact cells 

Regulation: Coupling efficiency;uncoupling, Uncoupler  Coupling state: LEAK, ROUTINE, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, TIP2k, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

O2k-Demo 

Further information

>> MiPNet10.04
  • Version 6: 2012-04-07
  • Version 1: 2005