{{Publication
{{Publication
|title=Garedew A, HΓΌtter E, Haffner B, Gradl P, Gradl L, Jansen-DΓΌrr P, Gnaiger E (2005) High-resolution respirometry for the study of mitochondrial function in health and disease. The OROBOROS Oxygraph-2k. Proc. 11th Congress Eur. Shock Soc., Vienna, Austria (Redl H, ed) Medimond, Bologna: 107-111.
|title=Garedew A, HΓΌtter E, Haffner B, Gradl P, Gradl L, Jansen-DΓΌrr P, Gnaiger E (2005) High-resolution respirometry for the study of mitochondrial function in health and disease. The Oroboros O2k. Proc 11th Congress Eur Shock Soc, Vienna, Austria (Redl H, ed) Medimond, Bologna:107-11.
|info=[http://www.oroboros.at/fileadmin/user_upload/2005_Garedew-Gnaiger_Europ_Shock_Soc.pdf Weblink]
|info=[[Media:Garedew 2005 Eur Shock Soc.pdf |'''Bioblast Access''']]
|authors=Garedew A, Huetter E, Haffner B, Gradl P, Gradl L, Jansen Duerr P, Gnaiger E
|authors=Garedew A, Huetter E, Haffner B, Gradl P, Gradl L, Jansen-Duerr P, Gnaiger Erich
|year=2005
|year=2005
|abstract=[[High-resolution respirometry]] with mitochondria, cells or biopsies is based on the unique features of the OROBOROS [[Oxygraph-2k]], combining instrumental design, electronics and task-specific DatLab software.
|journal=Medimond
Various respiratory states are analyzed with <0.4 million cells or <4 mg biopsy (muscle, liver) per assay. Complex substrate/inhibitor titration protocols are used to quantify functional properties of selected components of the respiratory chain. The electronic titration-injection micropump [[TIP-2k]] is applied for kinetics as a modular component of the Oxygraph-2k. [[DatLab]] 4 provides on-line instrumental background corrections of oxygen flux and on-line data analysis, and tabulated results are available at the end of an experiment. This sets a new standard for biomedical and clinical studies, combining high-resolution with instant diagnostic information.
|abstract=[[High-resolution respirometry]] with mitochondria, cells or biopsies is based on the unique features of the [[Oroboros O2k]], combining instrumental design, electronics and task-specific DatLab software.
|mipnetlab=AT_Innsbruck_Gnaiger E, AT_Innsbruck_Jansen Duerr P
Various respiratory states are analyzed with <0.4 million cells or <4 mg biopsy (muscle, liver) per assay. Complex substrate/inhibitor titration protocols are used to quantify functional properties of selected components of the respiratory chain. The electronic titration-injection micropump [[TIP2k]] is applied for kinetics as a modular component of the O2k. [[DatLab]] provides on-line instrumental background corrections of oxygen flux and on-line data analysis, and tabulated results are available at the end of an experiment. This sets a new standard for biomedical and clinical studies, combining high-resolution with instant diagnostic information.
|mipnetlab=AT Innsbruck Gnaiger E, AT Innsbruck Jansen-Duerr P, AT Innsbruck Oroboros, AT Kolsass WGT
|discipline=Mitochondrial Physiology
|discipline=Mitochondrial Physiology
}}
}}
{{Labeling
{{Labeling
|instruments=Oxygraph-2k, TIP2k
|area=Respiration, Instruments;methods
|organism=Human
|organism=Human
|tissues=Fibroblast
|tissues=Fibroblast
|preparations=Intact Cell; Cultured; Primary
|preparations=Intact cells
|kinetics=Inhibitor; Uncoupler
|topics=Uncoupler
|topics=Respiration; OXPHOS; ETS Capacity, Coupling; Membrane Potential
|couplingstates=OXPHOS
|instruments=Oxygraph-2k, TIP2k
|discipline=Mitochondrial Physiology
|discipline=Mitochondrial Physiology
}}
}}

Latest revision as of 04:16, 23 November 2021

Publications in the MiPMap
Garedew A, HΓΌtter E, Haffner B, Gradl P, Gradl L, Jansen-DΓΌrr P, Gnaiger E (2005) High-resolution respirometry for the study of mitochondrial function in health and disease. The Oroboros O2k. Proc 11th Congress Eur Shock Soc, Vienna, Austria (Redl H, ed) Medimond, Bologna:107-11.

Β» Bioblast Access

Garedew A, Huetter E, Haffner B, Gradl P, Gradl L, Jansen-Duerr P, Gnaiger Erich (2005) Medimond

Abstract: High-resolution respirometry with mitochondria, cells or biopsies is based on the unique features of the Oroboros O2k, combining instrumental design, electronics and task-specific DatLab software. Various respiratory states are analyzed with <0.4 million cells or <4 mg biopsy (muscle, liver) per assay. Complex substrate/inhibitor titration protocols are used to quantify functional properties of selected components of the respiratory chain. The electronic titration-injection micropump TIP2k is applied for kinetics as a modular component of the O2k. DatLab provides on-line instrumental background corrections of oxygen flux and on-line data analysis, and tabulated results are available at the end of an experiment. This sets a new standard for biomedical and clinical studies, combining high-resolution with instant diagnostic information.


β€’ O2k-Network Lab: AT Innsbruck Gnaiger E, AT Innsbruck Jansen-Duerr P, AT Innsbruck Oroboros, AT Kolsass WGT


Labels: MiParea: Respiration, Instruments;methods 


Organism: Human  Tissue;cell: Fibroblast  Preparation: Intact cells 

Regulation: Uncoupler  Coupling state: OXPHOS 

HRR: Oxygraph-2k, TIP2k 