The apparent excess E-P capacity factor (E-P coupling control factor), jExP = (E-P)/E = 1-P/E, is an expression of the relative limitation of OXPHOS capacity by the capacity of the phosphorylation system. jExP = 0.0 when OXPHOS is not limited by the phosphorylation system at zero ETS excess capacity, P=E, when the phosphorylation system does not exert any control over OXPHOS capacity. jExP increases with increasing control of the phosphorylation system over OXPHOS capacity. jExP = 1 at the limit of zero phosphorylation capacity. The OXPHOS state of mt-preparations is stimulated to ETS by uncoupler titration, which yields the excess E-P capacity, ExP=E-P.
Abbreviation: jExP
Reference: Flux control factor, Gnaiger 2014 MitoPathways
MitoPedia concepts:
Respiratory control ratio
Compare
- Β» OXPHOS control ratio, P/E
- Β» Excess E-R capacity factor, jExR = (E-R)/E = 1-R/E
- Β» ETS coupling efficiency, jβE = 1-L/E