Talk:Oroboros Ecosystem Agenda 2020: Difference between revisions
From Bioblast
No edit summary |
No edit summary |
||
Line 15: | Line 15: | ||
:::: [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Yellow-take care.png|40px|Take care]] '''Why the oxygen levels are different for the chambers?''' | :::: [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Yellow-take care.png|40px|Take care]] '''Why the oxygen levels are different for the chambers?''' | ||
::::::: What to do if the oxygen concentration is not 'normal' or is not the same for both chambers: - Β»[[Oxygen_calibration_-_DatLab#Troubleshooting | Oxygen calibration - troubleshooting]]Β« | ::::::: What to do if the oxygen concentration is not 'normal' or is not the same for both chambers: - Β»[[Oxygen_calibration_-_DatLab#Troubleshooting | Oxygen calibration - troubleshooting]]Β« | ||
:::: [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Yellow-take care.png|40px|Take care]] '''Unstable flux in OXPHOS''' | |||
::::::: Some substrates can't support respiration alone - Β»[[Pyruvate#Troubleshooting | Pyruvate - troubleshooting]]Β« |
Revision as of 10:20, 20 March 2020
For discussion
Here we discuss suggestions for the Oroboros Ecosystem Agenda 2020
- As part of the H2020 SME NextGen-O2k project we are developing a PhotoBiology module that will allow to study the effect of different light intensities on O2 consumption and production: Β»PhotoBiologyΒ«
- Do you perform a stirrer test during oxygen calibration?
- In DatLab 7.4, instrumental DL-Protocols guide you automatically towards performing the stirrer test in the process of air calibration. It shows immediately, if your OroboPOS has a satisfactory response time. Further details in MitoPedia: Β»Oxygen calibration - DatLab
- Do you perform a stirrer test during oxygen calibration?
- Is the noise of the βO2 slope negβ acceptable?
- If you are not certain that the noise of the βO2 slope negβ is within a suitable range or you want to confirm that your experimental data will not be affected, see further details: MiPNet06.03 POS-calibration-SOP
- Is the noise of the βO2 slope negβ acceptable?
Not sure if I choose the right O2k-support picture:
- Why the oxygen levels are different for the chambers?
- What to do if the oxygen concentration is not 'normal' or is not the same for both chambers: - Β» Oxygen calibration - troubleshootingΒ«
- Why the oxygen levels are different for the chambers?
- Unstable flux in OXPHOS
- Some substrates can't support respiration alone - Β» Pyruvate - troubleshootingΒ«
- Unstable flux in OXPHOS