Search results

From Bioblast
Results 21 โ€“ 41 of 52
Advanced search

Search in namespaces:

  • ...right|180px]]'''Volume-Calibration Ring''' (A or B) PVDF for O2k-Stoppers (2-mL [[O2k-chamber]]), white; attached to the [[Stopper\black PEEK\conical Sh ::::* Loosen the stopper fixation rings (A) and (B) with the Allen key (OroboPOS-Service Kit).
    1 KB (171 words) - 11:53, 11 November 2020
  • ...(O2k Quality Control)]] for the [[O2k-Open_Support#1._O2_sensor_test|O<sub>2</sub> sensor test]], the stirrer test is performed in the 'open' chamber in
    1 KB (227 words) - 11:42, 6 May 2024
  • |description=What are potential causes for '''different O<sub>2</sub> fluxes in the left and right chamber'''? ...ocedure described in the section '''Calibration and quality control of the OroboPOS (O2k-SOP)''' in [[O2_calibration_-_DatLab#Calibration_and_quality_control|
    2 KB (341 words) - 18:56, 6 November 2019
  • ...mber''': Duranยฎ glass polished, with standard operation volumes (''V'') of 2.0 mL or 0.5 mL (small chamber volume in the [[O2k-sV-Module]], 12 mm inner ...''' - [https://www.oroboros.at/index.php/product/o2k-chamber/ O2k-Chamber (2.0 mL)], [https://www.oroboros.at/index.php/product/o2k-chamber-sv/ O2k-Cham
    12 KB (1,709 words) - 13:03, 5 February 2024
  • ...esolution respirometry with the Oroboros O2k. Hands-on sessions range from OroboPOS technical service to respirometry experiments with substrate-uncoupler-inhi |OroboPOS service and O2k instrumental setup - overview with videoclips
    8 KB (952 words) - 15:45, 8 June 2020
  • ...tatus line|status line]], besides the DatLab version number (bottom), and (2) in windows [[O2k control]] [F7] and [[O2k configuration]]. ::::* Type of [[OroboPOS-Connector]]
    2 KB (373 words) - 08:50, 11 November 2019
  • ::::::::''16:30 - 17:15'' O2k setup (team 1 and 2); OroboPOS service (team 3 and 4) ...17:15 - 18:00'' O2k setup (team 3 and 4); OroboPOS service (team 1 and 2)
    7 KB (787 words) - 10:32, 11 April 2022
  • == Electrochemical NO and H<sub>2</sub>O<sub>2</sub> sensors == ...sensors. All amperometric sensors (NO, H<sub>2</sub>S, H<sub>2</sub>O<sub>2</sub>) that have the same connection can be used with the O2k.
    6 KB (883 words) - 11:50, 17 August 2022
  • ...k-Fluorometry for measurement of hydrogen peroxide, ATP production, Ca<sup>2+</sup> uptake capacity, mitochondrial membrane potential with fluorometric ...ality controls 1 ([[MiPNet06.03 POS-calibration-SOP |O2 sensor test]]) and 2 ([[MiPNet14.06 Instrumental O2 background |O2k-chamber test]]), which are e
    5 KB (667 words) - 14:56, 11 July 2022
  • ...you know that you can set a warning alarm for the lower limit of the O<sub>2</sub> concentration in DatLab 7? '''<br> - ยป[[Run_DL-Protocol/Set_O2_limit#Protocol_menu | '''Set O<sub>2</sub> limit in DatLab''']]ยซ <br>
    27 KB (4,026 words) - 11:53, 29 March 2021
  • |Introduction - OroboPOS service and O2k instrumental setup - overview with videoclips |Hands-on: OroboPOS service and O2k instrumental setup
    6 KB (698 words) - 15:40, 8 June 2020
  • |OroboPOS service and O2k instrumental setup - overview with videoclips |'''Hands-on''': OroboPOS service and O2k instrumental setup
    6 KB (750 words) - 10:56, 31 March 2021
  • ...esolution respirometry with the Oroboros O2k. Hands-on sessions range from OroboPOS technical service to respirometry experiments with substrate-uncoupler-inhi |2.77
    11 KB (1,464 words) - 15:47, 8 June 2020
  • [[File:Distributor training 2.jpeg|500px|right|Distributor training]] :::: 16:00 - 17:00 General questions (OroboPOS-Connector, quality controlโ€ฆ)
    3 KB (374 words) - 06:27, 13 May 2023
  • ...-wide distibution of the O2k. With completion of the development of DatLab 2 in cooperation with Dr. Michael Reck, the term "high-resolution respirometr ::::In '''[[Oroboros 1997| 1997]]''' Oroboros released DatLab 2, setting a new standard in software-supported high-resolution respirometry.
    8 KB (1,102 words) - 16:18, 22 February 2024
  • ...tration]]s in [[MiPNet14.06 Instrumental O2 background |instrumental O<sub>2</sub> background tests]]. It is not recommended to use dithionite in experi |chem formula=Na<sub>2</sub>S<sub>2</sub>O<sub>4</sub>
    9 KB (1,336 words) - 07:33, 13 October 2023
  • :::: Minimum duration: 2 days ...from instrumental setup and service of the polarographic oxygen sensor ([[OroboPOS]]) for instrumental quality control system, which is an essential component
    4 KB (577 words) - 15:03, 14 September 2021
  • |abbr=''J''ยฐ<sub>O<sub>2</sub></sub> ...e range of experimental oxygen levels by a standardized instrumental O<sub>2</sub> background test. The oxygen regime from air saturation towards zero o
    22 KB (3,238 words) - 15:29, 2 May 2024
  • ...oxygen partial pressure at the temperature defined by the experimenter; (''2'') zero oxygen calibration; (''3'') high stability of the POS signal tested ...ring an instrumental calibration run. '''Step <span style="background:red">2</span>''': Click on <span style="background:lightgrey">Calibrate and copy t
    26 KB (3,995 words) - 10:15, 7 October 2021
  • ''' [[OroboPOS| Polarographic oxygen sensor (POS)]] and O2k service''' ...potential ([[Safranin]]), ATP production ([[Magnesium green]]), and Ca<sup>2+</sup> ([[Calcium green]]). Further O2k-MultiSensor applications are covere
    8 KB (1,139 words) - 09:41, 1 June 2023
View ( | ) (20 | 50 | 100 | 250 | 500)
Cookies help us deliver our services. By using our services, you agree to our use of cookies.