Difference between revisions of "MiPNet09.12 O2k-Titrations"
From Bioblast
Beno Marija (talk | contribs) |
|||
Line 3: | Line 3: | ||
|info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/e/ef/MiPNet09.12_O2k-Titrations.pdf |Bioblast pdf]] »[http://www.bioblast.at/index.php/File:MiPNet09.12_O2k-Titrations.pdf Versions] | |info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/e/ef/MiPNet09.12_O2k-Titrations.pdf |Bioblast pdf]] »[http://www.bioblast.at/index.php/File:MiPNet09.12_O2k-Titrations.pdf Versions] | ||
|authors=Oroboros | |authors=Oroboros | ||
|year= | |year=2018-10-01 | ||
|journal=Mitochondr Physiol Network | |journal=Mitochondr Physiol Network | ||
|abstract='''Oroboros ( | |abstract='''Oroboros (2018) O2k manual titrations: SUIT protocols with mitochondrial preparations. Mitochondr Physiol Network 09.12(17): 1-2.''' | ||
A list of substrates, uncouplers, and inhibitors used in [[SUIT]] protocols in [[High-Resolution FluoRespirometry]], with information on abbreviations, stock concentrations, final experimental concentrations, volumes titrated into the 2 ml O2k-chamber, and syringes used for manual titrations. | A list of substrates, uncouplers, and inhibitors used in [[SUIT]] protocols in [[High-Resolution FluoRespirometry]], with information on abbreviations, stock concentrations, final experimental concentrations, volumes titrated into the 2 ml O2k-chamber, and syringes used for manual titrations. |
Revision as of 08:41, 2 October 2018
O2k manual titrations: SUIT protocols with mitochondrial preparations. |
» »Versions
Oroboros (2018-10-01) Mitochondr Physiol Network
Abstract: Oroboros (2018) O2k manual titrations: SUIT protocols with mitochondrial preparations. Mitochondr Physiol Network 09.12(17): 1-2.
A list of substrates, uncouplers, and inhibitors used in SUIT protocols in High-Resolution FluoRespirometry, with information on abbreviations, stock concentrations, final experimental concentrations, volumes titrated into the 2 ml O2k-chamber, and syringes used for manual titrations.
- » O2k-Protocols
- » Product: Oroboros O2k, O2k-Catalogue
• O2k-Network Lab: AT_Innsbruck_Oroboros
Labels: MiParea: Instruments;methods
Regulation: ADP, Inhibitor, Substrate, Uncoupler, Amino acid
HRR: O2k-Protocol
O2k-chemicals and media
Note: Titration of chemicals in respirometry
- Overshoots or short interruptions of the flux after the injection of chemicals do not have a meaning in respirometric measurements. A disturbance of the signal is only observed due to the injected chemical and does not represent mitochondrial respiration. With the addition of a chemical solved in ethanol a little bit of oxygen is always introduced, since ethanol has higher oxygen solubility than water.
Further information
- » MitoPedia: SUIT - Substrate-uncoupler-inhibitor-titration (SUIT) protocols for respirometry
- » MiPNet03.02 - Chemicals and media for respirometry
- » MiPNet19.14 - SOP for manual O2k-titrations with Hamilton microsyringes.