  • ...]]'''Volume-Calibration Ring''' (A or B) PVDF for O2k-Stoppers (2-mL [[O2k-chamber]]), white; attached to the [[Stopper\black PEEK\conical Shaft\central Port |info=[https://www.oroboros.at/index.php/product/volume-calibration-ring/ '''Product details and purchase information''']
    1 KB (171 words) - 11:53, 11 November 2020
  • ...ge:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]]'''Volume-Calibration Ring sV''' (A or B), white PVDF, attached to [[Stopper sV\black PEEK\conica |info=[https://www.oroboros.at/index.php/product/volume-calibration-ring-sv/ '''Product details and purchase information''']
    1 KB (184 words) - 11:25, 11 November 2020
  • ...etting started with the [[Oroboros O2k]] to guarantee a standard [[chamber volume]] of 2.0 mL.
    380 bytes (49 words) - 11:57, 25 March 2022
  • :::* Version 08 (2020-10-17) Section '''5.4. O2k-chamber volume calibration''' ::::# Instructions are added for the 0.5-mL O2k-chamber volume calibration ([[O2k-sV-Module]]).
    2 KB (198 words) - 11:43, 27 July 2023
  • ...iological sample, and all the components necessary for a smaller operation volume ''V'' of 0.5 mL. The current DatLab version is included in the delivery of == Titration to the 0.5-mL O2k-chamber ==
    3 KB (426 words) - 10:05, 14 September 2023
  • ...1.3 mm diameter; 50.6 mm length), [[Volume-Calibration Ring]] (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings, with 8 spare O-rings ([[O-ring ...O2k-FluoRespirometer manual]] for calibration of the 2-mL [[O2k-chamber]] volume, which is identical for PEEK and PVDF stoppers.
    1 KB (177 words) - 10:43, 11 November 2020
  • ...tential causes for '''different O<sub>2</sub> fluxes in the left and right chamber'''? ...experiments we get consistently higher fluxes in chamber A as compared to chamber B.
    2 KB (341 words) - 18:56, 6 November 2019
  • ...mm diameter; 48.9 mm length), [[Volume-Calibration Ring sV]] (A or B) for volume adjustment 0.5 mL; 2 mounted O-rings ([[O-ring sV\Viton\9.5x1 mm]]). {{Template:Keywords: Chamber volume}}
    776 bytes (95 words) - 10:43, 18 November 2020
  • ...1ePMu8&list=PLT4umseflf-m6O1sApyn9doi8vHNAKaIs&index=3 '''A2''' Insert O2k Chamber] ...be/zZI7O5zAruw]] [https://youtu.be/zZI7O5zAruw '''A4''' O2k-chamber volume calibration]
    9 KB (1,435 words) - 12:42, 14 November 2023
  • ...tube.com/watch?v=1MSsI1ePMu8&feature=youtu.be O2k-Videosupport: Insert O2k Chamber] .../watch?v=DuaEJc7FBjk&feature=youtu.be O2k-Videosupport: O2k Chamber volume calibration]
    2 KB (316 words) - 10:04, 29 March 2024
  • ...gas phase above the aqueous phase in the 2-mL [[O2k-chamber]], during air calibration or for injection of nitrogen, argon or oxygen into the gas phase; Stopper-S {{Template:Keywords: Chamber volume}}
    865 bytes (114 words) - 10:33, 11 November 2020
  • ...lary and conical basis; including [[Volume-Calibration Ring]] (A or B) for volume adjustment (1.5 to 3.2 mL); 2 mounted O-rings ([[O-ring\Viton\12x1 mm]]).
    809 bytes (111 words) - 16:27, 14 April 2021
  • ...s plots are shown for the left chamber in Graph 1 (top), and for the right chamber in Graph 2 (below). During data acquisition, a 30 min time range is frequen === 01 Calibration show Temp ===
    11 KB (1,780 words) - 13:28, 21 March 2022
  • ...pressure of oxygen [kPa], the aqueous solution is stirred rigorously in a chamber enclosing air at constant temperature. The concentration of oxygen, ''c''<s |info=[[MiPNet06.03 POS-calibration-SOP]], [[Oxygen calibration - DatLab]], [[Oxygen sensor test]]
    2 KB (263 words) - 11:01, 5 October 2020
  • ...e/1MSsI1ePMu8]] [https://youtu.be/1MSsI1ePMu8 O2k-Videosupport: Insert O2k Chamber] ...zAruw]] [https://youtu.be/zZI7O5zAruw O2k-Videosupport: O2k Chamber volume calibration]
    5 KB (754 words) - 12:50, 7 November 2023
  • ...n able to avoid any sample oxidative stress. During this procedure the O2k-chamber remains closed, decreasing disturbance of the system and allowing for quick ...can escape into the small bubble and then be extruded by fully closing the chamber. During the experiment re-oxygenations must be progressively performed in o
    5 KB (828 words) - 17:10, 31 January 2024
  • ::# Insert O2k Chamber ::# Chamber volume calibration
    3 KB (435 words) - 09:58, 27 September 2023
  • ...B will be set accordingly. Chamber B can be set to a different value than chamber A by overwriting the pre-filled values. The following values are available ...our sample by entering any combination of digits and numbers to chamber A. Chamber B will be set accordingly but can be changed to any other value by overwrit
    7 KB (1,153 words) - 13:36, 23 April 2024
  • ...>O<sub>2</sub></sub> in the absence of sample. Finally, zero O<sub>2</sub> calibration completes the sensor test. ...ly intervals. These results confirm the instrumental limit of detection of volume-specific O<sub>2</sub> flux at ±1 pmol∙s<sup>−1</sup>∙mL<sup>−1</s
    4 KB (503 words) - 13:10, 4 August 2022
  • |description=[[File:O2k-Chamber.jpg|right|180px]] ...with standard operation volumes (''V'') of 2.0 mL or 0.5 mL (small chamber volume in the [[O2k-sV-Module]], 12 mm inner diameter). The optical properties of
    12 KB (1,709 words) - 13:03, 5 February 2024