O2k-Catalogue: OroboPOS components

From Bioblast

Jump to: navigation, search
Description 26### O2k-Catalogue: OroboPOS components
Product ID 26###
Type O2k, Catalogue
Link Order information: @OROBOROS
Image 26###

O2k-Catalogue: OroboPOS - List of products

Title Description Product id Product image
O2k-Amperometric OroboPOS Twin-Channel O2k-Amperometric OroboPOS Twin-Channel: Two-channel variable polarization voltage; current/voltage converter for the polarographic oxygen sensor (POS); amplifyer with digital gain settings (1x, 2x, 4x, 8x); A/D converter; output in the range -10 V to 10 V. Integral component of the O2k-Main Unit. 20040
2 OroboPOS The 2 OroboPOS set (two polarographic oxygen sensors, POS) is included in the O2k-Core, shipped with the O2k in the O2k-Service Box. For details, see OroboPOS. 20600
OroboPOS.JPG
OroboPOS-Service Kit OroboPOS-Service_Kit, with O2k-Service Box including all oxygen sensor service accessories for membrane mounting and service of the OroboPOS. 20610-01
02k-Accessory Box.jpg
OroboPOS-Connector OroboPOS-Connector, with male connection to OroboPOS sensor head (POS) and with cable and male plug fitting into O2k-Main Unit. O2k-Core: 2 in O2k-Assembly Kit, mounted on the OroboPOS-Holders at the O2k-Main Unit. 22200-01
POS connector and cable connection.jpg
OroboPOS-Holder The OroboPOS-Holder (POS-Holder) is screwed into the copper block of the O2k-Main Unit, guiding the OroboPOS-Connector with the OroboPOS sensor head (POS) to the O2k-Chamber, and keeping the OroboPOS-Connector in a fixed position for sealing the O2k-Chamber with the OroboPOS-Seal Tip. In addition, the OroboPOS-Holder fixes the O2k-Chamber in an accurate rotational position by pressing against the angular cut of the glass chamber. O2k-Core: 2 in O2k-Assembly Kit, mounted on the O2k-Main Unit. 22300-01
OroboPOS The OroboPOS is a polarographic oxygen sensor (POS), with an amperometric mode of operation. With application of a polarization voltage (0.6 to 0.8 V), a current is obtained as an amperometric signal, which is converted to a voltage. Shipment: OroboPOS are protected in a transparent perspex vial screwed onto a blue POM base, with the OroboPOS-Membrane Ring arrested on the POS shaft between the POM base and the thicker part of the POS head which holds a O-ring\Viton\8x1 mm. 26000-01
OroboPOS sensor head.jpg
OroboPOS-Seal Tip OroboPOS-Seal Tip, black butyl rubber gasket with 3 mm pore. 4/Pck, for sealing the OroboPOS (sensor head) against the O2k-Chamber. Push the wetted OroboPOS-Seal Tip over the POS-sensor head, with the pore positioned centrally, not covering any peripheral area of the gold cathode. Do not stretch the gasket across the POS-sensor head. O2k-Core: in OroboPOS-Service Kit. 26110-01
POS seal tip.jpg
OroboPOS-Membrane Ring OroboPOS-Membrane Ring, PEEK, holds the membrane against the inner O-ring on the POS housing. For shipment in the O2k-accessory box, the OroboPOS is enclosed in a perspex housing. When the POS is uncsrewed from the blue base of the housing, the OroboPOS-Membrane Ring slides out from the POS shaft, and can be put in place with the OroboPOS-Mounting Tool during membrane application. 26120-01
POS membrane holder ring.jpg
O-ring\Viton\8x1 mm O-ring\Viton\8x1 mm: on OroboPOS sensor head. 26130-01
O-ring\Viton\9x1 mm O-ring\Viton\9x1 mm on OroboPOS-Mounting Tool. 26131-01
POS O-ring for sensor head or POS mounting tool.jpg
OroboPOS-Membranes OroboPOS-Membranes, FEP 25 µm; 40/Pck. O2k-Core: 2 Pck in OroboPOS-Service Kit. 26200-01
POS membranes.jpg
OroboPOS-Electrolyte Powder OroboPOS-Electrolyte Powder, KCl. O2k-Core: in OroboPOS-Service Kit. 26300-01
POS Electrolyte powder.jpg
OroboPOS-Mounting Tool OroboPOS-Mounting Tool for application of OroboPOS-Membranes, with O-ring\Viton\9x1 mm for holding the OroboPOS-Membrane Ring during membrane application. O2k-Core: in OroboPOS-Service Kit. 26400-01
POS mounting tool for membrane application.jpg
OroboPOS-Polishing Cloth OroboPOS-Polishing Cloth for cathode cleaning. O2k-Core: in OroboPOS-Service Kit. 26510-01
POS polishing cloth for cathode cleaning.jpg
OroboPOS-Polishing Powder OroboPOS-Polishing Powder for cathode cleaning. O2k-Core: in OroboPOS-Service Kit. 26520-01
POS polishing powder for cathode cleaning.jpg
Pen-Contact Oil Pen-Contact Oil, for stable low contact resistance between the OroboPOS head and the OroboPOS-Connector. O2k-Core: in OroboPOS-Service Kit. 26550-01
Pen contact oil.jpg
O2-Zero Powder O2-Zero Powder, dithionite (Na2S2O4), for zero-oxygen calibration of the OroboPOS. O2k-Core: in OroboPOS-Service Kit. 26600-01
O2-Zero Powder.jpg
Forceps for membrane application Forceps for membrane application: for OroboPOS and ISE membrane application; do not use for tissue preparation. Set: in OroboPOS-Service Kit and O2k-TPP+ and Ca2+ ISE-Module. 26700-01
Forcep for membrane application.jpg
Pipette\Plastic\1 ml ungraded Pipette\Plastic\1 ml ungraded, for filling electrolyte into the reservoir of the OroboPOS; in OroboPOS-Service Kit. 26800-01
Pipette Plastic 1 ml-ungraded.JPG
Personal tools
Namespaces
Variants
Actions
Navigation
Bioblast
Add or edit
Toolbox