| Title |
Description |
Product id |
Product image |
| O2k-Amperometric OroboPOS Twin-Channel |
O2k-Amperometric OroboPOS Twin-Channel: Two-channel variable polarization voltage; current/voltage converter for the polarographic oxygen sensor (POS); amplifyer with digital gain settings (1x, 2x, 4x, 8x); A/D converter; output in the range -10 V to 10 V. Integral component of the O2k-Main Unit. |
20040 |
|
| 2 OroboPOS |
The 2 OroboPOS set (two polarographic oxygen sensors, POS) is included in the O2k-Core, shipped with the O2k in the O2k-Service Box.
For details, see OroboPOS. |
20600 |
|
| OroboPOS-Service Kit |
OroboPOS-Service_Kit, with O2k-Service Box including all oxygen sensor service accessories for membrane mounting and service of the OroboPOS. |
20610-01 |
|
| OroboPOS-Connector |
OroboPOS-Connector, with male connection to OroboPOS sensor head (POS) and with cable and male plug fitting into O2k-Main Unit.
O2k-Core: 2 in O2k-Assembly Kit, mounted on the OroboPOS-Holders at the O2k-Main Unit. |
22200-01 |
|
| OroboPOS-Holder |
The OroboPOS-Holder (POS-Holder) is screwed into the copper block of the O2k-Main Unit, guiding the OroboPOS-Connector with the OroboPOS sensor head (POS) to the O2k-Chamber, and keeping the OroboPOS-Connector in a fixed position for sealing the O2k-Chamber with the OroboPOS-Seal Tip. In addition, the OroboPOS-Holder fixes the O2k-Chamber in an accurate rotational position by pressing against the angular cut of the glass chamber.
O2k-Core: 2 in O2k-Assembly Kit, mounted on the O2k-Main Unit. |
22300-01 |
|
| OroboPOS |
The OroboPOS is a polarographic oxygen sensor (POS), with an amperometric mode of operation. With application of a polarization voltage (0.6 to 0.8 V), a current is obtained as an amperometric signal, which is converted to a voltage.
Shipment: OroboPOS are protected in a transparent perspex vial screwed onto a blue POM base, with the OroboPOS-Membrane Ring arrested on the POS shaft between the POM base and the thicker part of the POS head which holds a O-ring\Viton\8x1 mm. |
26000-01 |
|
| OroboPOS-Seal Tip |
OroboPOS-Seal Tip, black butyl rubber gasket with 3 mm pore. 4/Pck, for sealing the OroboPOS (sensor head) against the O2k-Chamber. Push the wetted OroboPOS-Seal Tip over the POS-sensor head, with the pore positioned centrally, not covering any peripheral area of the gold cathode. Do not stretch the gasket across the POS-sensor head.
O2k-Core: in OroboPOS-Service Kit. |
26110-01 |
|
| OroboPOS-Membrane Ring |
OroboPOS-Membrane Ring, PEEK, holds the membrane against the inner O-ring on the POS housing. For shipment in the O2k-accessory box, the OroboPOS is enclosed in a perspex housing. When the POS is uncsrewed from the blue base of the housing, the OroboPOS-Membrane Ring slides out from the POS shaft, and can be put in place with the OroboPOS-Mounting Tool during membrane application. |
26120-01 |
|
| O-ring\Viton\8x1 mm |
O-ring\Viton\8x1 mm: on OroboPOS sensor head. |
26130-01 |
|
| O-ring\Viton\9x1 mm |
O-ring\Viton\9x1 mm on OroboPOS-Mounting Tool. |
26131-01 |
|
| OroboPOS-Membranes |
OroboPOS-Membranes, FEP 25 µm; 40/Pck.
O2k-Core: 2 Pck in OroboPOS-Service Kit. |
26200-01 |
|
| OroboPOS-Electrolyte Powder |
OroboPOS-Electrolyte Powder, KCl.
O2k-Core: in OroboPOS-Service Kit. |
26300-01 |
|
| OroboPOS-Mounting Tool |
OroboPOS-Mounting Tool for application of OroboPOS-Membranes, with O-ring\Viton\9x1 mm for holding the OroboPOS-Membrane Ring during membrane application.
O2k-Core: in OroboPOS-Service Kit. |
26400-01 |
|
| OroboPOS-Polishing Cloth |
OroboPOS-Polishing Cloth for cathode cleaning.
O2k-Core: in OroboPOS-Service Kit. |
26510-01 |
|
| OroboPOS-Polishing Powder |
OroboPOS-Polishing Powder for cathode cleaning.
O2k-Core: in OroboPOS-Service Kit. |
26520-01 |
|
| Pen-Contact Oil |
Pen-Contact Oil, for stable low contact resistance between the OroboPOS head and the OroboPOS-Connector.
O2k-Core: in OroboPOS-Service Kit. |
26550-01 |
|
| O2-Zero Powder |
O2-Zero Powder, dithionite (Na2S2O4), for zero-oxygen calibration of the OroboPOS.
O2k-Core: in OroboPOS-Service Kit. |
26600-01 |
|
| Forceps for membrane application |
Forceps for membrane application: for OroboPOS and ISE membrane application; do not use for tissue preparation.
Set: in OroboPOS-Service Kit and O2k-TPP+ and Ca2+ ISE-Module. |
26700-01 |
|
| Pipette\Plastic\1 ml ungraded |
Pipette\Plastic\1 ml ungraded, for filling electrolyte into the reservoir of the OroboPOS; in OroboPOS-Service Kit. |
26800-01 |
|